System-Related Functions
Copyright ©ITECH Electronic Co., Ltd.
58
⚫
Latch: When input an inhibit signal and the instrument output is turned OFF.
The ON/OFF button will be lighted off, the status bar of the LCD screen
displays INH warning icon. In this case, user need to remove the input signal
and press [Shift]+[Esc] to cleare protection, then manually turn on [On/Off]
again.
Digital IO-2
IO-1 pin can be set to
【
PS-claer
】
,
【
Input
】
,
【
Output
】
The default function is to clear the protected state. When the protection occurs,
the protection state can be cleared through this pin, so that the instrument can
continue to output normally.
IO-2 is bi-directional, that is, when the power supply is in a protected state, the
instrument can receive a pulse signal from an external input through IO-2 for
clean protection operation, or when the power supply is in a protected state, the
clean protection can generate a pulse signal from IO-2.
Digital IO-3
IO-3 pin can be set to
【
PS
】
,
【
Input
】
,
【
Output
】
The default function is protection state indicator. IO-3 pin will output high or low
level based on whether the instrument is under protection or not. Under normal
conditions (Not under protection), and when pin3 is under default setting (Not
Invert), pin 3 outputs high level; when the instrument is under protection, pin 3
outputs low level. When pin3 is set to Invert, the output level is completely
opposite.
Digital IO-4
IO-4 pin can be set to
【
Sync-in
】
,
【
Sync-out
】
,
【
Input
】
,
【
Output
】
This function can be used to simulate the six-phase output mode, in which one
IT7900 outputs a synchronous signal to another IT7900, and the second power
supply runs synchronously with the frequency and phase of the first power
supply to realize the six-phase output function.
【
Sync-in
】
: Synchronous input function, which is used to output frequency lock
or phase lock with the external signal. At this time, the machine synchronizes
the frequency or phase information input from the IO-4 pin.
【
Sync-out
】
: Synchronous output function, the IT7900 produces synchronous
signal to the outside, which is AC zero crossing pulse signal sent from the IO
port.
Digital IO-5
IO-5 can be set to
【
OnOff-status
】
,
【
Input
】
,
【
Output
】
The default function is to indicate the output state of the power supply, in case
of output is ON, output 5V, otherwise, output 0V.
When pin5 is set to Invert, the output level is completely opposite.
Digital IO-6
IO-6 can be set to
【
Trigger1-in
】
,
【
Trigger1-out
】
,
【
Input
】
,
【
Output
】
【
Trigger1-in
】
: The input trigger signal, the pulse signal sent to the IO-6 pin can
be used as the trigger source. Users can select as the trigger source of the