Operating manual: PHOTOMETER FM-4           17

5. 2.  Transport and Stocking 

 

Transport  the  device  in  original  packing  if  possible.  When  it  is  not  available  use 
protection air bubble foil and protect exposed areas with Styrofoam. If needed place it on 
wooden pallets. 
 
Temperature while transporting and stocking should wary between -25

 

°C and +55

 

°C. 

 
Avoid  long  time  stocking.  After  transport  and  mounting,  allow  at  least  1  hour  time  to 
settle down before commission. In case that device is not to be used for longer period, 
store it in dry, well ventilated place at room temperature! 

5. 3.  Disposal 

 
Lifetime of the device significantly depends on the way of use, installation, maintenance and 
the  working  conditions. Production  year  is  visible  on  the  back  side  sticker.  Deteriorated  or 
ruined device dispose to the place for industry electronic-components disposal according to 
local regulation. 
 
Components  particularly  danger  for  environment  (batteries,  chemicals,  etc.)  dispose  to 
special places. 
 
 
 
 

6. 

CE Declaration of Conformity 

 

CE  declaration  of conformity  ensures  that  device  is  safe  for  use  and it  has  been checked 
and tested to the specified standards. CE statement is enclosed. 
 
 
 

7. 

Warranty Obligations 

 

Manufacturer of the device ensures that the product will work in accordance to specification 
for the time of limited warranty of 1 year. For this time we take full responsibility and costs 
(transport  not  included)  for  removal  of  any  malfunction  due  to  materials  or  workmanship. 
Warranty does not cover any mechanical damage or damage being result of natural cause 
or unprofessional use. 

Содержание Photometer FM-4

Страница 1: ...Operating manual Photometer FM 4 Litostrojska cesta 44 d SI 1000 Ljubljana T 386 1 514 18 00 F 386 1 514 18 04 info itaia si www itaia si ELECTRONICS RESEARCH DEVELOPMENT...

Страница 2: ......

Страница 3: ...ation Port 6 2 4 2 Use of 230 V AC Contactor Outputs 7 2 5 CALIBRATION 7 3 PC SOFTWARE STREET LIGHT VISION 8 3 1 WRITING DATA TO THE PHOTOMETER 9 3 2 READING DATA FROM THE PHOTOMETER 10 3 3 SETTING UP...

Страница 4: ...F DEVICE MUST BE CARIED OUT BY QUALIFIED PERSONNEL WHEN CONNECTING DISCONNECT ELECTRICAL POWER FIRST DO NOT BLOCK ACCESS TO ELECTRICAL PARTS USED FOR EMERGENCY STOP CLEANING AND MAINTENANCE ALL METAL...

Страница 5: ...s disconnected during the time of mounting and connecting Check the voltage presence with an instrument Check grounding connection Provide protection against touching the parts under voltage Qualified...

Страница 6: ...F 386 1 514 18 04 info itaia si www itaia si Declaration of Conformity The device complies with relevant European directives CE declaration of conformity Electromagnetic compatibility ULRS no 132 2006...

Страница 7: ...foldings or joints When it is used to measure in tunnel light conditions it should be mounted at the height of app 4 5 metres and pointed to the spot one reach in 3 seconds at maximum allowed speed I...

Страница 8: ...6 contactor out D 230 V AC contactor out D 7 out out C 230 V AC contactor out C 8 out B 230 V AC contactor out B 9 out A 230 V AC contactor out A 10 PC GND 0 V DC programming control 11 RS 232 RX 12...

Страница 9: ...r the user 2 4 1 Serial Communication Port The photometer s selectable communication port can be configured for RS 232 or RS 485 Set jumpers J1 J3 to select the protocol Connection distance can be up...

Страница 10: ...LEDs and contactor outputs Green LEDs indicate estimated switch level combination no averaging delay due to current light condition Red LEDs indicate current status of 230 V AC outputs averaging affec...

Страница 11: ...tor photometer s working parameters Install the software to any folder on the computer running MS Windows 2000 or higher The program is executed by clicking SLV icon Graphical user interface of the pr...

Страница 12: ...th the combination used when the highest level specified is exceeded see Picture 3 Table 2 Averaging interval is the moving average of light level calculating time in minutes before contactor outputs...

Страница 13: ...ice matching ID After reading data is refreshed in all fields Light Level Read Manual setting reads light level and any other device s parameter by clicking Read button Use Auto setting to read light...

Страница 14: ...For RS 232 485 settings on the photometer see 2 4 1 Serial communication Port in this manual Picture 4 Photometer System Settings StreetLightVision software selects COM1 as the default If port is occu...

Страница 15: ...edure when there is another device with the same ID on the bus only Write new ID into the field and click New ID button The numerical data within 0 255 can be selected Make sure to write down new ID I...

Страница 16: ...uto to activate the data logging Table graph and data file are updated every time when Light Level data is read from photometer Logging interval is time in minutes between two readings The numerical d...

Страница 17: ...nths interval clean the housing 1 year interval and recalibrate 3 year interval Note The device requires regular checking and maintenance Keep your maintenance and service log up to date Shorten check...

Страница 18: ...rial port Note No communication note appears by unsuccessful communication with photometer check ID number of the device check power supply and data connection to the photometer Note Communication err...

Страница 19: ...A 5x20 mm Casing IP67 Aluminium Stainless steel ABS Size W x H x D 395 x 135 230 x 145 mm Weight 2 8 kg Fixture wall X Y adjustable fixture pole optional Communication port RS 232 485 9600 bps Contact...

Страница 20: ...conditions Production year is visible on the back side sticker Deteriorated or ruined device dispose to the place for industry electronic components disposal according to local regulation Components p...

Страница 21: ...Safety requirements for electrical equipment for measurement control and laboratory use Part1 General requirements SIST EN 61000 3 2 2006 EMC Part 3 2 Limits for harmonic current emissions equipment...

Страница 22: ...ist in case of improper use or use in discordance to this manual in case of mechanical damage in case of consequential damage due to failure or damage of other devices in case of natural or environmen...

Страница 23: ...V 1 2 rev 12 2012...

Страница 24: ...Litostrojska cesta 44 d SI 1000 Ljubljana T 386 1 514 18 00 F 386 1 514 18 04 info itaia si www itaia si...