Operating manual: PHOTOMETER FM-4           7

2. 4. 2. Use of 230 V AC Contactor Outputs 

 
Outputs  can  be  directly  connected  to  the  coil-side  of  contactors  for  light-chain  switching 
(check  contactor’s  coil  voltage!).  Use  PC  software  to  distribute  switching  combinations. 
Example is shown at Table 2.  

 

regulation

light

output

A

B

C

D

LED

level

condition

pin

9

8

7

6

green,red

1

2

3

4

0

B<L1

230 V AC

/

/

/

ON

/

/

/

1

B>L1;B<L2

/

230 V AC

/

/

/

ON

/

/

2

B>L2;B<L3

/

230 V AC 230 V AC

/

/

ON

ON

/

3

B>L3;B<L4

/

/

/

230 V AC

/

/

/

ON

4

B>L4

230 V AC 230 V AC

/

230 V AC

ON

ON

/

ON

 

 

Table 2: Indicating LEDs and contactor outputs 

 
 
Green LEDs indicate estimated switch-level combination (no averaging delay) due to current 
light condition. Red LEDs indicate current status of 230 V AC outputs (averaging affected). 
For example : At first level LED-A is lit when light conditions are within the limit set for L1. 
After preset averaging time, the red LED-A and contactor output A will be switched on. 
 

2. 5.  Calibration 

 
Each photometer is incarefully factory calibrated. Calibration date and information are stored 
in device’s memory and also visible on side sticker. Recommended recalibration interval is 2 
years.  
 
 
 
 
 
 
 
 
 

Your calibration data 

 
 
Factory calibration: 
 
 
 
Place of installation:___________________________________ date:_____________ 
 
 
 
Recalibrations: 
 

Содержание Photometer FM-4

Страница 1: ...Operating manual Photometer FM 4 Litostrojska cesta 44 d SI 1000 Ljubljana T 386 1 514 18 00 F 386 1 514 18 04 info itaia si www itaia si ELECTRONICS RESEARCH DEVELOPMENT...

Страница 2: ......

Страница 3: ...ation Port 6 2 4 2 Use of 230 V AC Contactor Outputs 7 2 5 CALIBRATION 7 3 PC SOFTWARE STREET LIGHT VISION 8 3 1 WRITING DATA TO THE PHOTOMETER 9 3 2 READING DATA FROM THE PHOTOMETER 10 3 3 SETTING UP...

Страница 4: ...F DEVICE MUST BE CARIED OUT BY QUALIFIED PERSONNEL WHEN CONNECTING DISCONNECT ELECTRICAL POWER FIRST DO NOT BLOCK ACCESS TO ELECTRICAL PARTS USED FOR EMERGENCY STOP CLEANING AND MAINTENANCE ALL METAL...

Страница 5: ...s disconnected during the time of mounting and connecting Check the voltage presence with an instrument Check grounding connection Provide protection against touching the parts under voltage Qualified...

Страница 6: ...F 386 1 514 18 04 info itaia si www itaia si Declaration of Conformity The device complies with relevant European directives CE declaration of conformity Electromagnetic compatibility ULRS no 132 2006...

Страница 7: ...foldings or joints When it is used to measure in tunnel light conditions it should be mounted at the height of app 4 5 metres and pointed to the spot one reach in 3 seconds at maximum allowed speed I...

Страница 8: ...6 contactor out D 230 V AC contactor out D 7 out out C 230 V AC contactor out C 8 out B 230 V AC contactor out B 9 out A 230 V AC contactor out A 10 PC GND 0 V DC programming control 11 RS 232 RX 12...

Страница 9: ...r the user 2 4 1 Serial Communication Port The photometer s selectable communication port can be configured for RS 232 or RS 485 Set jumpers J1 J3 to select the protocol Connection distance can be up...

Страница 10: ...LEDs and contactor outputs Green LEDs indicate estimated switch level combination no averaging delay due to current light condition Red LEDs indicate current status of 230 V AC outputs averaging affec...

Страница 11: ...tor photometer s working parameters Install the software to any folder on the computer running MS Windows 2000 or higher The program is executed by clicking SLV icon Graphical user interface of the pr...

Страница 12: ...th the combination used when the highest level specified is exceeded see Picture 3 Table 2 Averaging interval is the moving average of light level calculating time in minutes before contactor outputs...

Страница 13: ...ice matching ID After reading data is refreshed in all fields Light Level Read Manual setting reads light level and any other device s parameter by clicking Read button Use Auto setting to read light...

Страница 14: ...For RS 232 485 settings on the photometer see 2 4 1 Serial communication Port in this manual Picture 4 Photometer System Settings StreetLightVision software selects COM1 as the default If port is occu...

Страница 15: ...edure when there is another device with the same ID on the bus only Write new ID into the field and click New ID button The numerical data within 0 255 can be selected Make sure to write down new ID I...

Страница 16: ...uto to activate the data logging Table graph and data file are updated every time when Light Level data is read from photometer Logging interval is time in minutes between two readings The numerical d...

Страница 17: ...nths interval clean the housing 1 year interval and recalibrate 3 year interval Note The device requires regular checking and maintenance Keep your maintenance and service log up to date Shorten check...

Страница 18: ...rial port Note No communication note appears by unsuccessful communication with photometer check ID number of the device check power supply and data connection to the photometer Note Communication err...

Страница 19: ...A 5x20 mm Casing IP67 Aluminium Stainless steel ABS Size W x H x D 395 x 135 230 x 145 mm Weight 2 8 kg Fixture wall X Y adjustable fixture pole optional Communication port RS 232 485 9600 bps Contact...

Страница 20: ...conditions Production year is visible on the back side sticker Deteriorated or ruined device dispose to the place for industry electronic components disposal according to local regulation Components p...

Страница 21: ...Safety requirements for electrical equipment for measurement control and laboratory use Part1 General requirements SIST EN 61000 3 2 2006 EMC Part 3 2 Limits for harmonic current emissions equipment...

Страница 22: ...ist in case of improper use or use in discordance to this manual in case of mechanical damage in case of consequential damage due to failure or damage of other devices in case of natural or environmen...

Страница 23: ...V 1 2 rev 12 2012...

Страница 24: ...Litostrojska cesta 44 d SI 1000 Ljubljana T 386 1 514 18 00 F 386 1 514 18 04 info itaia si www itaia si...

Отзывы: