![Isokern Magnum 28 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/isokern/magnum-28/magnum-28_installation-operation-maintenance-and-owners-manual_2093409057.webp)
ANCHOR
PLATE
INSWOOL
BLANKET
SMOKE DOME
TOP PLATE
METAL
FLUE
Class A Metal Flue
MAGNUM fireplaces are tested and listed for use with
factory-built metal, Class “A” (solid fuel) chimneys as an option.
Any Class “A” or UL 103 listed metal chimney system is accetable
for use on an Isokern system. (Figure 117)
Class “A” Metal Flue Types:
The selected factory-built metal chimney for use with the
fireplaces, at a minimum, must be listed by a recognized agency
for solid fuel and as tested to UL 103, for continuous use of one
thousand degrees (1000°) Fahrenheit and intermittent use of
seventeen hundred degrees (1700°) Fahrenheit.
The factory-built metal flue design can be from the following
types:
1. Non-insulated completely thermal siphoning,
double-wall, air-cooled solid fuel rated chimneys listed to UL 103,
ULC S629.
2. Double-wall with solid-pack insulation.
3. A combination of double-wall, solid-pack insulation and air
space (triple-wall).
4. Triple-wall air space solid fuel chimney.
5. Listed chimney liners conforming with the seventeen hundred
degree (1700°) Fahrenheit requirements of UL 1777 or ULCS635
or ULC640 may also be used with Isokern fireplaces.
Notes:
The selected, approved chimney manufacturer must
provide the masonry anchor plate designed to fit their flue system.
(Figure 118)
All chimneys and chimney liners must be installed in
accordance with the manufacturer’s installation instructions and
under the terms of their listing for use with open faced fireplaces.
Minimum flue size for the Magnum fireplace is twelve
and three-quarter inches (12-3/4”) inside diameter.
Maximum height of a metal flue system is not required as
all the load can be taken off the firebox.
FIGURE 117
FIGURE 118
FIGURE 119
FIGURE 120