![Isokern Magnum 28 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/isokern/magnum-28/magnum-28_installation-operation-maintenance-and-owners-manual_2093409013.webp)
B
B
A
D
C
A
FRAMED OP'G.
MINIMUM
FRAMED OPENIN
G
2'-5 1/2"
13
Rough Framing Dimensions
Corner Location Layout
Rough Framing Dimensions
FIGURE 4
FIGURE 5
Model
Width
Height
Depth
A
B
C
Model 28
38 1/2”
71”
29.5”
Model 36
46”
71”
29.5”
Model 42
52”
71”
29.5”
Model 48
56”
71”
29.5”
Model 60
78”
87”
29.5”
Model 72
89”
87”
29.5”
Notes:
A. “B” includes the MAGNUM 3” thick base plate. “B” is reduced by
3” if the base plate is eliminated to create a “flush hearth”.
B. “Raised hearth” requires additional rough opening height at “B”
equal to the height of the raised hearth detail.
C. Rough framing dimension for width “A” allows for the required
1-1/2” clearance at the sides of the MAGNUM fireplace.
D. Rough framing dimension for depth “C” allows for the required
1-1/2” clearance at the back of the MAGNUM fireplace.
The following chart of dimensions is intended to aid in the positioning of
an MAGNUM fireplace in a corner condition
where the DM 54 chimney must turn 45° degrees to align with overhead
framing.
Firebox
A
B
C
D
Model 28 33 1/2” 18 1/4”
24”
65 1/2”
Model 36
43”
16 3/4”
32”
78 3/4”
Model 42
49”
26 1/2”
36”
83”
Model 48
53”
28 1/2”
39”
85 3/4”
Model 60
73 1/2” 39”
53 1/2”
102 1/2”
Model 72
85 1/2” 45”
62”
111”
To turn flue 45°, first set one offset block on the firebox so that
the chimney offsets 3” toward the back of the firebox. (Figure 5)
Set a DM 54 outer casing onto this offset block so that the outer
casing is at 45° to the firebox and square to the overhead framing system.
Run the vertical DM 54 chimney through the overhead framing.
More offset blocks can be used - if necessary to align with
overhead framing - before running the vertical DM 54 chimney outer
casing and liner.
Note:
Support the third offset down to footings and at each third offset
block thereafter (see page 47).
Содержание Magnum 28
Страница 9: ...Component List Dimensions 28 36 42 48 9...
Страница 46: ...46 DM 54 Chimney System Lateral Support cont FIGURE 92 FIGURE 93...