Manual No. 0158A
64/68
IWB
−
IWX Series (Overseas Use) Service Manual
Text layout 2 (for data output command)
Receiving text
Scale data demand 1
Command
Terminator
Character
O
8
CR
LF
Code
(4FH)
(38H)
(0DH)
(0AH)
Function: Outputs one time instantly
after receiving.
Scale data demand 2
Command
Terminator
Character
O
9
CR
LF
Code
(4FH)
(39H)
(0DH)
(0AH)
Function: Outputs one time after
receiving when verifying that
the transmission condition
meets.
Responding text
Affirmative response (data output)
Preset output message
Condition: When executing normally within 1 second (for the 08
command).
When verifying that the data output condition meets (for the
09 command).
Timing:
After command is executed.
Negative response
Command
Character
NAK
Condition: Outside the scale operation range.
No output in 1 second (for the 08 command).
Code
(15H)
Received invalid text.
Received invalid command.
Timing: Upon receiving an invalid text/command.
When verifying that scale is outside the operation range.
One second after receiving the first character of a command.