![ISHIDA IWB Series Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/ishida/iwb-series/iwb-series_service-manual_2092775055.webp)
Manual No. 0158A
54/68
IWB
−
IWX Series (Overseas Use) Service Manual
Section 4. Replacing and Adjusting Load Cell
Specifications of load cell
Type
Model
Rated capacity
Rated output
Input
resistance
Output
resistance
Insulation
resistor
IWB/X/Q-150
LC'AT-200'
200kg
2.3mV/V
±
15%
2000
∼
2600
Ω
2000
∼
2600
Ω
10G
Ω
IWB/X/Q-30
LC'AT-50'
50kg
2.3mV/V
±
15%
2000
∼
2600
Ω
2000
∼
2600
Ω
10G
Ω
IWB-6
LC'AT-10'
10kg
2.3mV/V
±
15%
2000
∼
2600
Ω
2000
∼
2600
Ω
10G
Ω
Structural drawing for replacement in IWB/IWX/IWQ -30/50
Hexagon-socket head bolt A
•
IW -30 M8
×
30 2bolts
•
IW -150 M10
×
30 4 bolts
Platter support
Hexagon-socket head bolt B
•
IW -30 M8
×
65 2bolts
•
IW -150 M10
×
65 4 bolts
Fl t h
Flat washer
Spacer
IW-150 only
Nylon clamp
F
Four-corner limit face
rear
B
Base
Case’ bottom
Four-corner limit face front
Lower limit bolt
M5
×
8
Flat washer
•
IW -30 5mm 1 piece
•
IW -30 5mm 2 pieces
Load cell
•
IW -30 LC’AT-50’
•
IW -150 LC’AT-200’
Spacer
•
IW –150 only
Hexagon nut M5
Four-corner limit bolt
M5
×
30 4 bolts
Spring washer
Differences between 30 and 150 in IW series
•
Different part dimensions .
•
The parts configuration is common except –150.
•
Number and dimension of screw holes differ between the load
cell AT-50 and AT-200.
•
Number of flat washer used for the lower limit bolts differs.