![ISHIDA IWB Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/ishida/iwb-series/iwb-series_service-manual_2092775064.webp)
Manual No. 0158A
63/68
IWB
−
IWX Series (Overseas Use) Service Manual
Text layout 1 ( for function execution command)
Receiving text
Tare subtraction command
Command
Terminator
Character
T
[SP]
CR
LF
Code
(54H)
(20H)
(0DH)
(0AH)
Function: Performs actual tare weight
subtraction.
Zero adjustment command
Command
Terminator
Character
Z
[SP]
CR
LF
Code
(5AH)
(20H)
(0DH)
(0AH)
Function: Performs zero adjustment.
Preset call-up demanding command
Command
Terminator
Character
P
No.
CR
LF
Code
(50H)
*
(0DH)
(0AH)
Function: Performs preset call-up.
*Preset No. 0
∼
9 (30H
∼
39H) and 10 (“:”/40H)
(0
∼
5 for the Japanese specifications)
Responding text
Affirmative response
Command
Character
ACK
Code
(06H)
Condition: When executing normally within 1 second.
Timing:
After command is executed.
Negative response
Command
Character
NAK
Condition: Outside the command operation range.
Not executed in 1 second.
Code
(15H)
Received invalid text.
Received invalid command.
Timing:
Upon receiving an invalid text/command.
Verified that it is outside the command operation range.
One second after receiving the first character of a
command.