Chapter
5
Operation
5-15
On the bottom line of the time card, the following note is
printed:
CARD DELETED WITH CARRYOVER
This serves to inform the user that the time card and its
totals are no longer saved in the time recorder
4.
Remove the card.
The following display appears:
5.
Insert the new time card.
Hint:
The function remains active for about 5 seconds. For
safety reasons, if no card is inserted during this time, the
display will revert to the date and time indicating a return to
the normal operating mode. This process can be repeated
as often as is required, but starting from step 1.
The time recorder checks to ensure that the new time card
number is not in its memory. If the number already exists, it
rejects the new card with the display message:
CARD BEING USED
If the time recorder accepts the card, the new card number
with the carried over totals from the old time card are
written into the memory of the new card.
Additionally a punch according to the status of the person is
printed on the new card, i.e. if an employee is present an
"OUT" punch, if an employee is absent an "IN" punch is
printed.
Afterward the record of the old time card number is deleted
automatically.
6.
Remove the new card.
The recorder returns to the normal operating mode
displaying date and time.
7.
Punching with the new card.
The employee has to be set to the original status with a
further punching.
Содержание PERFECT 2030
Страница 1: ...PERFECT 2030 Operating Manual ...
Страница 2: ......
Страница 10: ...0 4 Contents Chapter 0 ...
Страница 20: ...2 6 Features Chapter 2 ...
Страница 32: ...3 12 Installation Chapter 3 ...
Страница 83: ...Chapter 4 Getting Started 4 51 Continue with next value Hint Use E to return to the input level ...
Страница 88: ...4 56 Getting Started Chapter 4 ...
Страница 110: ...5 22 Operation Chapter 5 ...
Страница 118: ...6 8 Trouble Shooting Chapter 6 ...
Страница 119: ...Chapter 7 Maintenance 7 1 Chapter 7 Maintenance Ribbon Change 7 2 Cleaning the Time Recorder 7 4 ...
Страница 123: ...Appendix A Technical Specifications A 1 Appendix A Technical Specifications ...
Страница 125: ...Appendix B Default Program Settings B 1 Appendix B Default Program Settings ...
Страница 127: ...Appendix B Default Program Settings B 3 Signal Operation Master clock function Card validity duration ...
Страница 128: ...B 4 Default Program Settings Appendix B ...
Страница 129: ...Appendix C Program Settings C 1 Appendix C Program Settings ...
Страница 133: ...Appendix D Conversion table D 1 Appendix D Conversion Table for Minute Print Formats ...
Страница 135: ...Appendix E Sales and Service Dealer E 1 Appendix E Local Sales and Service Dealer ...
Страница 137: ......