iMC-B / iMC-V Operating Instruction
page - 14
➄
Digital output port
- 8-pin, left to right A2.1
– A2.8
The mounted I/O board has two digital output ports each with 8 digital switches. The
first output port (A1.1
– A1.8) is internal used for signalization. The second output
port can free configured by the user
Properties
-
8
x electronic outputs
-
Imax < 350mA, 24VDC
-
Thermic protection
-
short circuit proof
Wiring
pin
output
description
1
Out1
output A2.1
2
Out2
output A2.2
3
Out3
output A2.3
4
Out4
output A2.4
5
Out5
output A2.5
6
Out6
output A2.6
7
Out7
output A2.7
8
Out8
output A2.8
Please note the default connection of the first output
–port (A1.1
– A1.8) in the control software Remote / ProNC under the menu
entry „Signalization“.
These outputs are directly wired with the modules inside the
controller. You cannot longer use these outputs in the user
program!
➅
Digital input port
- 8-pin, left to right E1.1
– E1.8
The mounted I/O board has two digital input ports each with 8 digital inputs. The
second input port (E2.1
– E2.8) is internal used for signalization. The first input port
can free configured by the user.
Properties
- opt coupled inputs
- input current ca. 8mA
Wiring
pin
input
description
1
In 1
Input E1.1
2
In 2
Input E2.2
3
In 3
Input E2.3
4
In 4
Input E2.4
5
In 5
Input E2.5
6
In 6
Input E2.6
7
In 7
Input E2.7
8
In 8
Input E2.8