iMC-B / iMC-V Operating Instruction
page - 13
➂
External additional control console connector
- 15-pin Sub-D (optional)
This connector is used if an additional isel control console is used.
pin signal
description
1
EM_STOP_1
Emergency stop channel 1, connector 1.1
2
EM_STOP_1
Emergency stop channel 1, connector 1.2
3
EM_STOP_2
Emergency stop channel 2, connector 2.1
4
EM_STOP_2
Emergency stop channel 2, connector 2.1
5
GND
GND control console
6
LAMP ACK
Output ACK lamp
7
ACK_1
Acknowledge channel 1, connector 1.1
8
ACK_1
Acknowledge channel 1, connector 1.2
9
ACK_2
Acknowledge channel 2, connector 2.1
10 ACK_2
Acknowledge channel 2, connector 2.2
11 COVER_1
Connector for cover button, connector 1.1
12 COVER_1
Connector for cover button, connector 1.2
13 COVER_2
Connector for cover button, connector 2.1 (option)
14 COVER_2
Connector for cover button, connector 2.1 (option)
15 n.v.
The maximum length of the connection cable for the hand control
unit / CNC control panel should not exceed 5m.
➃
Cover
connector
- 9-pin Sub-D- socket
Use this connector to integrate a cover or door control in the security circuit of the
controller.
pin
description
1
+ coil break contact
2
switch 1.1
3
switch 1.2
4
switch 2.1
5
switch 2.2
6
- coil break contact
7, 8, 9 not used