17
Group access: Channel ON / OFF
(Read-write /Write access)
Read-write
Byte
DATA_ID
Controller (DLC = 1):
Bit
7
6
5
4
3
2
1
0
Check Channels ON or OFF
Designation
DATA
_DIR
Data
1
1
1
0
0
1
1
0
0
Description
read
⇓
Response module (DLC = 3)
Byte
DATA_ID
DATA_1
DATA_0
Bit
7
6
5
4
3
2
1
0
7
...
0
7
0
Designation
DATA
_DIR
Data
0
1
1
0
0
1
1
0
0 x15
...
x8 x7
...
x0
Description
write
x0
⇒
Bit for Channel 0
x
n
= 1
⇒
Channel ON
:
x7
⇒
Bit for Channel 7
x
n
= 0
⇒
Channel OFF
Write
(Controller [DLC = 3]: Channels shut ON or OFF define)
Byte
DATA_ID
DATA_1
DATA_0
Bit
7
6
5
4
3
2
1
0
7
...
0
7
...
0
Designation
DATA
_DIR
Data
0
1
1
0
0
1
1
0
0 x15
x8 x7
x0
Description
write
x0
⇒
Bit for Channel 0
x
n
= 1
⇒
Channel ON
:
x7
⇒
Bit for Channel 7
x
n
= 0
⇒
Channel OFF
Group access: Emergency cut-off
(Write access)
Controller (DLC = 3): Channels ‘Emergency cut-off’
Byte
DATA_ID
DATA_1
DATA_0
Bit
7
6
5
4
3
2
1
0
7
...
0
7
...
0
Designation
DATA
_DIR
Data
0
1
1
0
1
0
1
0
0 x15
x8 x7
x0
Description
write
x7 ... x0:
for x
n
= 1:
Channel 7 ... Channel 0
Channels cut-off without ramp