S p e z i a l e l e k t r o n i k G m b H
iseg
c/o ROTECH
Email: [email protected]
Phone ++ 49 351 / 26 95 - 260
Spezialelektronik
Bautzner Landstr. 45
http://www.iseg-hv.com
Fax
++ 49 351 / 26 95 - 261
20
GmbH
D - 01454 Rossendorf
Germany
Group access: Serial number, software release and CAN message configuration
(Read-write/ Write access
)
Read-write
Byte
DATA_ID
Controller (DLC = 1):
Bit
7
6
5
4
3
2
1
0
Read serial number and software release module
Designation
DATA
_DIR
Data
1
1
1
1
0
0
0
0
0
Description
read
⇓
Response module (DLC = 7)
Byte
DATA_ID
DATA_5
DATA_4
DATA_3
DATA_2
DATA_1
DATA_0
Bit
7 6 5 4 3 2 1 0 BCD BCD BCD BCD BCD BCD BCD BCD BCD BCD BCD BCD
Designation
DATA
_DIR
Data
0
1 1 1 0 0 0 0 0
z6
z5
z4
z3
z2
z1
p2
y3
y2
y1
p1
c1
Description
write
6 BCD Serial number
3 BCD Soft-
ware release
c1: 1 BCD existing channels
Write
(Controller [DLC = 2]: Write a new CAN message configuration)
Byte
DATA_ID
DATA_0
Bit
7
6
5
4
3
2
1
0
BCD
BCD
Designation
DATA
_DIR
Data
0
1
1
1
0
0
0
0
0
0
x
Description
write
x = 2:
with iseg Standard-CAN message
ID9 is always dominant
x = 4:
with iseg Active-CAN message
ID9 is recessive