Group access: Module nominal values
(Read-write access)
Byte
DATA_ID
Controller (DLC = 1):
Bit
7
6
5
4
3
2
1
0
Read Voltage and Current nominal values of the module
Designation
DATA
_DIR
Data
1
1
1
1
1
0
1
0
0
Description
read
⇓
Response module (DLC = 5)
Byte
DATA_ID
DATA_3
DATA_2
DATA_1
DATA_0
Bit
7
6
5
4
3
2
1
0
7
...
0
7
...
0
7
...
0
7
...
0
Designation
DATA
_DIR
Data
0
1
1
1
1
0
1
0
0
x
...
x
x
...
x
x
...
x
x
...
x
Description
write
Mantissa
V
max
Exponent
V
max
Mantissa
I
max
Exponent
I
max
Group access: Status3 Current limit
(Read-write access)
Byte
DATA_ID
Controller (DLC = 1):
Bit
7
6
5
4
3
2
1
0
Check if the output current the software current trip per
Designation
DATA
_DIR
channel exceeds
Data
1
1
1
1
1
1
0
0
0
Description
read
⇓
Response module (DLC = 3)
Byte
DATA_ID
DATA_1
DATA_0
Bit
7
6
5
4
3
2
1
0
7
...
0
7
...
0
Designation
DATA
_DIR
Data
0
1
1
1
1
1
0
0
0 x15
...
x8 x7
...
x0
Description
write
x0
⇒
Status for Channel 0
x
n
= 0
⇒
Channel ok
:
x7
⇒
Status for Channel 7
x
n
= 1
⇒
Output current
has been exceeding the
programmable current trip.
If the measured output current exceeds the programmed current trip then the corresponding bits will be set.
The output voltage is not present and the channel is ‘OFF’ (Bit o = 0 in ‘Status channel’). A programmed
current limit with value zero has no effect to the current flow.
The setting bits in DATA_1 and DATA_0, the bit t in ‘Status channel’ and the bit z in ‘General status module’
will be reset after this access.
With help of the ‘Group access’ ‘Switch
ON
/OFF’ the concerning channels are switched ‘ON’ again.