Optidrive
ODV
‐
2
User
Guide
Revision
1.00
www.invertek.co.uk
54
15.
Parameter
Change
Tables
The
following
tables
can
be
used
to
enter
parameter
changes
made
to
the
drive
as
a
result
of
commissioning
and
to
provide
future
reference.
P1-01
Max Speed Limit
P3-03
User PID Differential Time Constant
P1-02
Min Speed Limit
P3-04
User PID Operating Mode
P1-03 Acceleration
Ramp
Time
P3-05
User PID Reference Select
P1-04
Deceleration Ramp Time
P3-06
User PID Digital Reference
P1-05
Stop Mode
P3-07
User PID Controller Output High Limit
P1-06
Energy Optimiser
P3-08
User PID Controller Output Low Limit
P1-07
Motor Rated Voltage
P3-09
User PID Output Control
P1-08
Motor Rated Current
P3-10
User PID Feedback Select
P1-09
Motor Rated Frequency
P3-11
PID Error To Enable Ramps
P1-10 Motor
Rated
Speed
P3-12
PID Feedback Value Display Scaling
Factor
P1-11
V/F Voltage Boost
P3-13
PID Feedback Wake-Up Level
P1-12
Control Mode
P3-14
Standby Active Speed
P1-13
Digital Inputs Function Select
P3-15
2
nd
User PID Digital Reference
P1-14
Extended Menu Access Code
P4-02
Motor Parameter Auto-Tune
P2-01
Preset Speed 1
P5-01
Fieldbus Drive Address
P2-02
Preset Speed 2
P5-03
Modbus / Bacnet Baudrate
P2-03
Preset Speed 3
P5-04
Modbus / Bacnet Data Format
P2-04
Preset Speed 4
P5-05
Comms Loss Timeout
P2-05
Preset Speed 5/ Clean Speed 1
P5-06
Communications Loss Action
P2-06
Preset Speed 6/ Clean Speed 2
P5-07
Field-Bus Ramp Control
P2-07
Preset Speed 7/ Boost Speed 1
P5-08
Any-Bus Output Process Data 4
P2-08
Preset Speed 8/ Boost Speed 2
P6-01
Firmware Upgrade Enable
P2-09
Skip Frequency Centrepoint
P6-02
Auto Thermal Management
P2-10
Skip Frequency Band
P6-03
Auto-Reset Delay Time
P2-11
Analog Output 1 Function Select
P6-04
User Relay Hysteresis Band
P2-12
Analog Output 1 Format
P6-10
Enable PLC Operation
P2-13
Analog Output 2 Function Select
P6-11
Speed Hold Time On Enable
P2-14
Analog Output 2 Format
P6-12
Speed Hold Time On Disable
P2-15
User Relay 1 Output Function Select
P6-18
DC Injection Braking Voltage
P2-16
User Relay 1 Upper Limit
P6-22
Reset Cooling Fan Run-Time
P2-17
User Relay 1 Lower Limit
P6-23
Reset kWh Meter
P2-18
User Relay 2 Output Function Select
P6-24
Service Time Interval
P2-19
User Relay 2 Upper Limit
P6-25
Reset Service Indicator
P2-20
User Relay 2 Lower Limit
P6-26
Analog Output 1 Scaling
P2-21
Display Scaling Factor
P6-27
Analog Output 1 Offset
P2-22
Display Scaling Source
P6-28
P0-80 Display Value Index
P2-23
Zero Speed Holding Time
P6-29
Save User Parameters As Default
P2-24
Effective Switching Frequency
P6-30
Level 3 Access Code
P2-25
Fast Deceleration Ramp Time
P7-01
Rs Value
P2-26
Spin Start Enable
P7-04
Magnetizing Current
P2-27
Standby Mode
P7-11
Pulse Width Minimum Limit
P2-28
Slave Speed Scaling Control
P7-12
V/F Mode Magnetising Period
P2-29
Slave Speed Scaling Factor
P8-01
Stir Interval Time
P2-30
Analog Input 1 Format
P8-02
Stir Active Time
P2-31
Analog Input 1 Scaling
P8-03
Clean Function Setup
P2-32
Analog Input 1 Offset
P8-04
Clean Time Setup
P2-33
Analog Input 2 Format
P8-05
Clean Ramp Time
P2-34
Analog Input 2 Scaling
P8-06
Current Monitor Mode Enable
P2-35
Analog Input 2 Offset
P8-07
Current Bandwidth
P2-36
Start Mode Select
P8-08
Current Monitor Trip Delay Time
P2-37
Keypad Restart Speed
P8-09
Fire Mode Logic
P2-38
Mains Loss Stop Control
P8-10
Fire Mode Speed
P2-39
Parameter Lock
P8-11
Bypass Mode On Fault
P2-40
Extended Parameter Access Code
Definition
P8-12
Bypass Mode On Fire
P3-01
User Pid Proportional Gain
P8-13
Bypass Contactor Change Over Time
P3-02
User PID Integral Time Constant
P8-14
Pump Staging Function Select