![Invertek Drives Optidrive HVAC Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/invertek-drives/optidrive-hvac-series/optidrive-hvac-series_user-manual_2085076004.webp)
Optidrive
ODV
‐
2
User
Guide
Revision
1.00
www.invertek.co.uk
4
Declaration
of
Conformity:
Invertek
Drives
Ltd
hereby
states
that
the
Optidrive
ODP
‐
2
product
range
conforms
to
the
relevant
safety
provisions
of
the
Low
Voltage
Directive
2006/95/EC
and
the
EMC
Directive
2004/108/EC
and
has
been
designed
and
manufactured
in
accordance
with
the
following
harmonised
European
standards:
EN
61800
‐
5
‐
1:
2003
Adjustable
speed
electrical
power
drive
systems.
Safety
requirements.
Electrical,
thermal
and
energy.
EN
61800
‐
3
2
nd
Ed:
2004
Adjustable
speed
electrical
power
drive
systems.
EMC
requirements
and
specific
test
methods
EN
55011:
2007
Limits
and
Methods
of
measurement
of
radio
disturbance
characteristics
of
industrial,
scientific
and
medical
(ISM)
radio
‐
frequency
equipment
(EMC)
EN60529
:
1992
Specifications
for
degrees
of
protection
provided
by
enclosures
Electromagnetic
Compatibility
All
Optidrives
are
designed
with
high
standards
of
EMC
in
mind.
All
versions
suitable
for
operation
on
Single
Phase
230
volt
and
Three
Phase
400
volt
supplies
and
intended
for
use
within
the
European
Union
are
fitted
with
an
internal
EMC
filter.
This
EMC
filter
is
designed
to
reduce
the
conducted
emissions
back
into
the
supply
via
the
power
cables
for
compliance
with
harmonised
European
standards.
It
is
the
responsibility
of
the
installer
to
ensure
that
the
equipment
or
system
into
which
the
product
is
incorporated
complies
with
the
EMC
legislation
of
the
country
of
use.
Within
the
European
Union,
equipment
into
which
this
product
is
incorporated
must
comply
with
the
EMC
Directive
2004/108/EC.
When
using
an
Optidrive
with
an
internal
or
optional
external
filter,
compliance
with
the
following
EMC
Categories,
as
defined
by
EN61800
‐
3:2004
can
be
achieved:
Drive
Type
/
Rating
EMC
Category
Cat
C1
Cat
C2
Cat
C3
1
Phase,
230
Volt
Input
ODV
‐
2
‐
x2xxx
‐
xxBxx
No
additional
filtering
required
Use
shielded
motor
cable
3
Phase,
400
Volt
Input
ODV
‐
2
‐
x4xxx
‐
xxAxx
Use
External
Filter
OD
‐
Fx34x
No
additional
filtering
required
Use
screened
motor
cable
Note
For
motor
cable
lengths
greater
than
100m,
an
output
dv
/
dt
filter
must
be
used,
please
refer
to
the
Invertek
Stock
Drives
Catalogue
for
further
details
All
rights
reserved.
No
part
of
this
User
Guide
may
be
reproduced
or
transmitted
in
any
form
or
by
any
means,
electrical
or
mechanical
including
photocopying,
recording
or
by
any
information
storage
or
retrieval
system
without
permission
in
writing
from
the
publisher.
Copyright
Invertek
Drives
Ltd
©
2011
All
Invertek
Optidrive
HVAC
units
carry
a
2
year
warranty
against
manufacturing
defects
from
the
date
of
manufacture.
The
manufacturer
accepts
no
liability
for
any
damage
caused
during
or
resulting
from
transport,
receipt
of
delivery,
installation
or
commissioning.
The
manufacturer
also
accepts
no
liability
for
damage
or
consequences
resulting
from
inappropriate,
negligent
or
incorrect
installation,
incorrect
adjustment
of
the
operating
parameters
of
the
drive,
incorrect
matching
of
the
drive
to
the
motor,
incorrect
installation,
unacceptable
dust,
moisture,
corrosive
substances,
excessive
vibration
or
ambient
temperatures
outside
of
the
design
specification.
The
local
distributor
may
offer
different
terms
and
conditions
at
their
discretion,
and
in
all
cases
concerning
warranty,
the
local
distributor
should
be
contacted
first.
The
contents
of
this
User
Guide
are
believed
to
be
correct
at
the
time
of
printing.
In
the
interest
of
a
commitment
to
a
policy
of
continuous
improvement,
the
manufacturer
reserves
the
right
to
change
the
specification
of
the
product
or
its
performance
or
the
contents
of
the
User
Guide
without
notice.
This
User
Guide
is
for
use
with
version
1.00
Firmware.
User
Guide
Revision
1.00
Invertek
Drives
Ltd
adopts
a
policy
of
continuous
improvement
and
whilst
every
effort
has
been
made
to
provide
accurate
and
up
to
date
information,
the
information
contained
in
this
User
Guide
should
be
used
for
guidance
purposes
only
and
does
not
form
the
part
of
any
contract.