Optidrive ODP-2ETHEG-IN User Guide Revisions 1.00 

 

www.invertekdrives.com 

5

 

 

2

 
Gener

al 

In

fo

rm

ati

on
 

2.

 

General Information 

2.1.

 

Overview 

ERROR LED Indicator 

 

Serial Port 1 

 

 

COMM LED Indicator 

Serial Port 2 

 

 

 

 

 

 

 

Ground Tab 

 

 

 

 

 

 

 

 

Ethernet Port P2 

Module Status LED 

 

 

 

Network Status LED 

 

 

Ethernet Port P1 

 

 

 

 

 

 

 

 

 

2.2.

 

Labelling 

The OPT-2-ETHEG-IN has two labels, as shown below. 

Top Label : 

 

Provides the MAC ID and PR ID Data for the 
module 
 
Side Label : 

 

Provides, the model code and serial 
number data 

 

 

2.3.

 

Connection Ports 

The interface connects to the Ethernet IP network and slave drive via the built in connection ports. 

Port 

Function 

P1 

Ethernet Port 1 

P2 

Ethernet Port 2 

IOIOI 1 

RJ45 Drive Data Connection 

IOIOI 2 

RJ45 Aux equipment Connection 

 

2.4.

 

Status Indicator LEDs 

Status LED 

Function 

NS 

EtherNet/IP Network Status Indicator 

MS 

MS: EtherNet/IP Network Status Indicator 

COMM 

COMM: Modbus Communication Indicator ( OPC-2-ETHIG-IN <-> Drive ) 

ERROR 

Modbus Error Indicator (OPC-2-ETHIG-IN <-> Drive ) 

 
 
 

Содержание OPT-2-ETHEG-IN

Страница 1: ...OPT 2 ETHEG IN Ethernet IP Interface Installation and Operating Instructions Installation Operating Instructions...

Страница 2: ...on 8 4 1 Overview 8 4 2 Connection Diagram 8 4 3 Grounding 8 5 Drive Parameter Settings 9 5 1 Overview 9 5 2 Optidrive Communication Parameters Overview 9 6 Operation 11 6 1 Overview 11 6 2 Configurat...

Страница 3: ...transport receipt of delivery installation or commissioning The manufacturer also accepts no liability for damage or consequences resulting from inappropriate negligent or incorrect installation inco...

Страница 4: ...achinery Directive 2006 42 EC Safety of Machinery In particular the machine manufacturer is responsible for ensuring that the electrical equipment complies with EN60204 1 and providing a disconnecting...

Страница 5: ...and PR ID Data for the module Side Label Provides the model code and serial number data 2 3 Connection Ports The interface connects to the Ethernet IP network and slave drive via the built in connecti...

Страница 6: ...active Steady flashing Yellow Modbus protocol TX RX active ERROR State Indication Steady Off Modbus protocol TX RX Status OK Steady Red Non recoverable internal fault Modbus communications circuit fau...

Страница 7: ...C 3 2 General The Ethernet IP interface is intended for mounting inside a control cabinet adjacent to the drive The unit should be mounted in a vertical position only on a flat flame resistant vibrati...

Страница 8: ...onnects via an RJ45 cable which also supplies the power to the OPT 2 ETHEG IN from the 24 Volt output of the Optidrive 4 2 Connection Diagram Optional Drive Keypad OPT 2 OPORT IN OPT 2 OPPAD IN RJ45 C...

Страница 9: ...signal must still be provided at the control terminals digital input 1 P 14 Extended Menu Access code 0 65535 0 Enables access to Extended and Advanced Parameter Groups This parameter must be set to...

Страница 10: ...status bit 1 indicates digital input 2 status etc 3 Analog Input 2 Signal Level 0 to 1000 0 to 100 0 4 Drive Heatsink Temperature 0 to 100 0 to 100 C P5 12 Fieldbus Process Data Output Word 3 Select...

Страница 11: ...3 address 1 For Drive specific allocation refer to Drive Manual and or Ethernet IP EDS file For Drive specific read write limitations refer to Drive Manual and or Ethernet IP EDS file The following c...

Страница 12: ...No Function 1 Fault Reset Request 3 0 Normal Operation 1 Coast Stop 4 No function 5 6 7 6 5 2 PDI Word 2 Drive Speed Reference The drive speed reference value has one decimal place e g commanded valu...

Страница 13: ...information for each code Refer to the relevant drive User Guide for further information on the cause and possible solutions for each fault No Fault Description 00 No Fault 01 Brake channel over curre...

Страница 14: ...Status Displays the status of the drive digital inputs where Bit 0 Digital Input 1 Bit 1 Digital Input 2 etc A bit value of 1 means the input is ON If an external I O module is connected to the drive...

Страница 15: ...xxxxxxx where xxxxxxxxxx PR ID value shown on the top product label as described in section 2 2 Both of the above values can be modified via the Web Server or Ethernet IP Class 0xF4 The Webserver cont...

Страница 16: ...rror status will be displayed Status State Indication Data Submitted Data has been submitted to OPT 2 ETHEG IN awaiting reply Data Read Write Error An error occurred data was not stored Resource Busy...

Страница 17: ...ethods Class Service 0x0F Parameter 0x0E Get_Attribute_Single Individual parameter Read Write Instance 1 holding register 0 0x10 Set_Attribute_Single 0x44 Modbus Object 0x4E Read_Holding_Registers Mul...

Страница 18: ...EDS Hardware Installation Tool 6 9 2 Configure the IP Address Configure the OPT 2 ETHEG IN IP address using either the OPT 2 ETHEG IN Web Server see section 6 7 3 or using RSLinx as follows Launch RS...

Страница 19: ...cal Data 7 1 Environmental Ambient Temperature Storage and Transportation 40 60 C 40 140 F Operating 10 50 C 14 122 F UL Approved 40 50 C 104 122 F Without UL approval Altitude Operating 1000m UL appr...

Страница 20: ...Optidrive ODP 2ETHEG IN User Guide Revisions 1 00 20 www invertekdrives com 7 Technical Data 82 EIPMN IN_V1 00...

Отзывы: