Invertek Drives OPT-2-ETHEG-IN Скачать руководство пользователя страница 3

Optidrive ODP-2ETHEG-IN User Guide Revisions 1.00 

 

www.invertekdrives.com 

3

 

 

1

 
In

trod

u

ct

ion
 

Declaration of Conformity 

Invertek Drives Limited  
Offas Dyke Business Park  
Welshpool  
Powys, UK  
SY21 8JF 

Invertek Drives Ltd hereby states that the OPT-2-ETHEG-IN conforms to the relevant safety provisions of the following council directives: 
 

2014/30/EU (EMC) and 2014/35/EU (LVD) 

 
Design and manufacture is in accordance with the following harmonised European standards: 

EN 61800-5-1: 2003 

Adjustable speed electrical power drive systems. Safety requirements. Electrical, thermal and energy. 

EN 61800-3 2

nd

 Ed: 2004 

Adjustable speed electrical power drive systems. EMC requirements and specific test methods 

EN 55011: 2007 

Limits and Methods of measurement of radio disturbance characteristics of industrial, scientific and medical (ISM) 
radio-frequency equipment (EMC) 

EN60529 : 1992 

Specifications for degrees of protection provided by enclosures 

Electromagnetic Compatibility 

All Optidrives are designed with high standards of EMC in mind. All versions suitable for operation on Single Phase 230 volt and Three Phase 400 
volt supplies and intended for use within the European Union are fitted with an internal EMC filter. This EMC filter is designed to reduce the 
conducted emissions back into the mains supply via the power cables for compliance with the above harmonised European standards. 
It is the responsibility of the installer to ensure that the equipment or system into which the product is incorporated complies with the EMC 
legislation of the country of use, and the relevant category. Within the European Union, equipment into which this product is incorporated 
must comply with the EMC Directive 2004/108/EC. This User Guide provides guidance to ensure that the applicable standards may be achieved. 
 
All rights reserved. No part of this User Guide may be reproduced or transmitted in any form or by any means, electrical or mechanical including 
photocopying, recording or by any information storage or retrieval system without permission in writing from the publisher. 

Copyright Invertek Drives Ltd © 2017 

All Invertek Optidrive units carry a 2 year warranty against manufacturing defects from the date of manufacture. The manufacturer accepts no 
liability for any damage caused during or resulting from transport, receipt of delivery, installation or commissioning. The manufacturer also 
accepts no liability for damage or consequences resulting from inappropriate, negligent or incorrect installation, incorrect adjustment of the 
operating parameters of the drive, incorrect matching of the drive to the motor, incorrect installation, unacceptable dust, moisture, corrosive 
substances, excessive vibration or ambient temperatures outside of the design specification. 
 
The local distributor may offer different terms and conditions at their discretion, and in all cases concerning warranty, the local distributor 
should be contacted first. 

 

This user guide is the “original instructions” document. All non-English versions are translations of the “original instructions”.  

Contents of this User Guide are believed to be correct at the time of printing. In the interest of a commitment to a policy of continuous 
improvement, the manufacturer reserves the right to change the specification of the product or its performance or the contents of the User 
Guide without notice. 

This User Guide is for use with version 1.00 Firmware. 

User Guide Revision 1.00

 

Invertek Drives Ltd adopts a policy of continuous improvement and whilst every effort has been made to provide accurate and up to date 
information, the information contained in this User Guide should be used for guidance purposes only and does not form the part of any 
contract. 

 

This manual is intended as a guide for proper installation. Invertek Drives Ltd cannot assume responsibility for the compliance 
or the non-compliance to any code, national, local or otherwise, for the proper installation of this drive or associated 
equipment. A hazard of personal injury and/or equipment damage exists if codes are ignored during installation. 

 

This Optidrive contains high voltage capacitors that take time to discharge after removal of the main supply. Before working 
on the drive, ensure isolation of the main supply from line inputs. Wait ten (10) minutes for the capacitors to discharge to safe 
voltage levels. Failure to observe this precaution could result in severe bodily injury or loss of life. 

 

Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved 
should install, adjust, operate, or service this equipment. Read and understand this manual and other applicable manuals in 
their entirety before proceeding. Failure to observe this precaution could result in severe bodily injury or loss of life. 

 
 

 

Содержание OPT-2-ETHEG-IN

Страница 1: ...OPT 2 ETHEG IN Ethernet IP Interface Installation and Operating Instructions Installation Operating Instructions...

Страница 2: ...on 8 4 1 Overview 8 4 2 Connection Diagram 8 4 3 Grounding 8 5 Drive Parameter Settings 9 5 1 Overview 9 5 2 Optidrive Communication Parameters Overview 9 6 Operation 11 6 1 Overview 11 6 2 Configurat...

Страница 3: ...transport receipt of delivery installation or commissioning The manufacturer also accepts no liability for damage or consequences resulting from inappropriate negligent or incorrect installation inco...

Страница 4: ...achinery Directive 2006 42 EC Safety of Machinery In particular the machine manufacturer is responsible for ensuring that the electrical equipment complies with EN60204 1 and providing a disconnecting...

Страница 5: ...and PR ID Data for the module Side Label Provides the model code and serial number data 2 3 Connection Ports The interface connects to the Ethernet IP network and slave drive via the built in connecti...

Страница 6: ...active Steady flashing Yellow Modbus protocol TX RX active ERROR State Indication Steady Off Modbus protocol TX RX Status OK Steady Red Non recoverable internal fault Modbus communications circuit fau...

Страница 7: ...C 3 2 General The Ethernet IP interface is intended for mounting inside a control cabinet adjacent to the drive The unit should be mounted in a vertical position only on a flat flame resistant vibrati...

Страница 8: ...onnects via an RJ45 cable which also supplies the power to the OPT 2 ETHEG IN from the 24 Volt output of the Optidrive 4 2 Connection Diagram Optional Drive Keypad OPT 2 OPORT IN OPT 2 OPPAD IN RJ45 C...

Страница 9: ...signal must still be provided at the control terminals digital input 1 P 14 Extended Menu Access code 0 65535 0 Enables access to Extended and Advanced Parameter Groups This parameter must be set to...

Страница 10: ...status bit 1 indicates digital input 2 status etc 3 Analog Input 2 Signal Level 0 to 1000 0 to 100 0 4 Drive Heatsink Temperature 0 to 100 0 to 100 C P5 12 Fieldbus Process Data Output Word 3 Select...

Страница 11: ...3 address 1 For Drive specific allocation refer to Drive Manual and or Ethernet IP EDS file For Drive specific read write limitations refer to Drive Manual and or Ethernet IP EDS file The following c...

Страница 12: ...No Function 1 Fault Reset Request 3 0 Normal Operation 1 Coast Stop 4 No function 5 6 7 6 5 2 PDI Word 2 Drive Speed Reference The drive speed reference value has one decimal place e g commanded valu...

Страница 13: ...information for each code Refer to the relevant drive User Guide for further information on the cause and possible solutions for each fault No Fault Description 00 No Fault 01 Brake channel over curre...

Страница 14: ...Status Displays the status of the drive digital inputs where Bit 0 Digital Input 1 Bit 1 Digital Input 2 etc A bit value of 1 means the input is ON If an external I O module is connected to the drive...

Страница 15: ...xxxxxxx where xxxxxxxxxx PR ID value shown on the top product label as described in section 2 2 Both of the above values can be modified via the Web Server or Ethernet IP Class 0xF4 The Webserver cont...

Страница 16: ...rror status will be displayed Status State Indication Data Submitted Data has been submitted to OPT 2 ETHEG IN awaiting reply Data Read Write Error An error occurred data was not stored Resource Busy...

Страница 17: ...ethods Class Service 0x0F Parameter 0x0E Get_Attribute_Single Individual parameter Read Write Instance 1 holding register 0 0x10 Set_Attribute_Single 0x44 Modbus Object 0x4E Read_Holding_Registers Mul...

Страница 18: ...EDS Hardware Installation Tool 6 9 2 Configure the IP Address Configure the OPT 2 ETHEG IN IP address using either the OPT 2 ETHEG IN Web Server see section 6 7 3 or using RSLinx as follows Launch RS...

Страница 19: ...cal Data 7 1 Environmental Ambient Temperature Storage and Transportation 40 60 C 40 140 F Operating 10 50 C 14 122 F UL Approved 40 50 C 104 122 F Without UL approval Altitude Operating 1000m UL appr...

Страница 20: ...Optidrive ODP 2ETHEG IN User Guide Revisions 1 00 20 www invertekdrives com 7 Technical Data 82 EIPMN IN_V1 00...

Отзывы: