background image

11 Restoring factory defaults

To reset the device to factory settings:

1. Press and hold RESET button for 10 to 15 seconds 
2. Green LED will start flashing 2 times a second (Nano Relay Output), the display 

will show:

 

rSt

 (Nano Relay Output PoE).

3. Release the reset button.

With factory defaults restored the module settings are as follows:

DHCP: enabled

IP address: 192.168.111.15

IP mask: 255.255.255.0

User name: admin

Password: admin00

12 Firmware update

The   device   has   the   ability   to   update   the   firmware.   The   software   update   program   is 
provided as a *.bin file.

Warning! 

Incorrect use of the update feature may damage the reader. Make sure that 

undisturbed power is provided to the device for duration of programming. 

To update the software:

check the 

Enable TFTP Bootloader

 option, which is located in the Administration 

tab,

run the Windows command line (Start-> Run enter 'cmd' and confirm with the 
Enter key),

go to the directory where the .bin file is located

enter the command:

tftp

 -i <address_ip_of the reader> 

PUT

 file.bin

where: <address_ip_of the reader> is the IP Address of the reader
file.bin – the file with the update program 

Programming takes 1-2 minutes. End of programming confirms the message 'File
Transferred'.

For   correct   functioning   of   the   reader,   after   the   update   operation   the  „

Enable   TFTP 

Bootloader

” option has to be switched off. 

Step-by-step instruction for firmware updates is available at 

https://inveo.com.pl

.

The   latest   instructions   and   software   are   available   on   the   site 

https://inveo.com.p

 

 l  

.

User manual Nano Relay Output PoE / Nano Relay Output

Page 

29

 of 

29

[B02a]

Содержание Nano Relay Output

Страница 1: ...User manual The Relay Output Module Nano Relay Output PoE Nano Relay Output Soft 1 21 INVEO s c ul Rzemie lnicza 21 43 340 Kozy tel 48 33 444 65 87 www inveo com pl info inveo com pl...

Страница 2: ...principles of safety and maintenance Please also keep the user manual so that you can read it during later use Attention The manufacturer is not liable for any damage caused by improper use of the de...

Страница 3: ...S FOR THE DEVICE CONFIGURATION 12 6 3 SECURITY SETTINGS AND ADMINISTRATION 14 7 THE DEVICE FUNCTIONS 15 7 1 OUTPUT CONTROL 15 7 2 CONFIGURATION OF THE OUTPUT CHANNEL 15 7 3 DESTINATION CLIENT M2M 17 7...

Страница 4: ...injury or damage to the device Important information and guidelines Following this guidelines makes the use of the device easier Attention The screenshots in this manual can be dissimilar from actual...

Страница 5: ...The manufacturer undertakes to comply with the contract of guarantee if the following conditions are met all repairs alterations extensions and device calibrations are performed by the manufacturer o...

Страница 6: ...humidity from 30 to 75 atmospheric pressure from 700 to 1060hPa Recommended transport conditions surrounding temperature from 40 C to 85 C relative humidity from 5 to 95 atmospheric pressure from 700...

Страница 7: ...DC 10 24VDC screw terminals 3 5mm Power consumption max 1 5W Outputs 1 output Output type relay NO Max current 1A 30VDC Engage time 10ms Disengage time 5ms Communication 1 port Ethernet 10Mbps PoE IE...

Страница 8: ...veo protocol User application TCP protocol available for user Description of the module connectors LAN LAN connection and PoE IEEE 802 3af power supply RESET switch used to enabling DHCP service check...

Страница 9: ...is supplied through the PoE adapter Outputs 1 output Output type relay NO Max current 1A 30VDC Engage time 10ms Disengage time 5ms Communication 1 port Ethernet 10Mbps passive PoE 12 24VDC power supp...

Страница 10: ...nd line programs MODBUS TCP protocol SNMP protocol HTTP protocol MQTT Inveo protocol User application TCP protocol available for user Description of the module connectors LAN LAN network and Passive P...

Страница 11: ...t box and click on Change IP button In a new opened dialog box settings such as IP address MASK GATEWAY DNS1 DNS2 and the Host name can be changed Please save correct settings by choosing Change butto...

Страница 12: ...Connections choose the related controller and right click on Properties After selecting this option configuration window will show up Next choose Internet Protocol TCP IP double click on it and enter...

Страница 13: ...s the IP address of the reader Gateway network gateway Subnet Mask IP subnet mask DNS1 DNS2 DNS servers addresses Destination IP the IP address of the server or of the external device in the M2M conne...

Страница 14: ...Enable Program Access a service of access by a computer program Windows Linux and TCP IP protocol operating on port 9761 Enable MODBUS TCP Protocol enables Modbus TCP server Enable SNMP enables SNMP p...

Страница 15: ...n of the output channel The user can configure the output channel settings of the device Settings can be customized in the Channel tab Power on state determines the output status after switching on th...

Страница 16: ...ed mode one pulse mode o In TimeBased mode if ton 0 and toff 0 after triggering the output the relay will stay disengaged for toff and then it will engage for ton o In TimeBased mode if ton 0 and toff...

Страница 17: ...eceiving messages external devices To enable the service enter the Administration tab and select Enable Program Access and confirm with the Save Config button Configuration of devices sending alarm st...

Страница 18: ...e format 1 UDP Ch x the function uses the connectionless protocol i e the UDP protocol Number Ch x is selected output channel in an external device e g LanTick which will be enabled when the channel s...

Страница 19: ...CRC CRC SOF CMD CH F_ID OUT OUT R1 R2 R3 R4 MOD 256 Format 2 The frame in the 2 format is sent as a string Output state Output state value 1 means active output 0 means inactive output HEX value STRI...

Страница 20: ...ans active output 0 means inactive output An example of a frame received by the server GET nano php mac 123456789012 io 1 address MAC 123456789012 io 1 the output is enabled The TCP frame can be handl...

Страница 21: ...ile link Then select the Save link as option Download the file to the MIB Browser program The basic parameters that can be read from the Nano Relay Output module can be found in the table Name Format...

Страница 22: ...listening on port 9761 TCPRel out 1 host 192 168 111 15 port 9761 on 7 6 Linux control program The output state can be checked by Linux command line To use the Linux control program enable the Progra...

Страница 23: ...ter 0x05 Write Single Coil 0x06 Write Single Register 0x0F Write Multiple Coils 0x10 Write Multiple Registers MODBUS TCP Coils Address Name R W Description 1000 On1 R W Enable disable the relay MODBUS...

Страница 24: ...te and additionally at each change Application configuration MQTT client Address mqtt inveo com pl Port 1883 User name nanouser User password nanouser Topic nanoO MAC After click Show Info the setting...

Страница 25: ...y state on 00000001 on Output state in 00000000 in In the Nano Relay Output module always 0 counter1 0 counter1 In the Nano Relay Output module always 0 temp1 0 0 temp1 In the Nano Relay Output module...

Страница 26: ...192 168 111 15 stat php w n 2 dev null grep out awk F out print 3 cut c8 Reading the name of the module curl u admin admin00 http 192 168 111 15 stat php w n 2 dev null grep prod_name awk F prod_name...

Страница 27: ...0x0A 0x00 0x00 0x00 0x00 0x00 0x0B 0x38 OK Read channels state dec 15 100 x x x x x x x x 115 CH7 CH0 hex 0x0F 0x64 x x x x x x x x 0x73 CH7 CH0 Read device name dec 15 200 x x x x x x x x 215 String...

Страница 28: ...protocol port UDP 161 9 Checking the IP address To check the current IP address of the device Nano Relay Output PoE only 1 Press and hold the reset button until the display shows the four parts of th...

Страница 29: ...r duration of programming To update the software check the Enable TFTP Bootloader option which is located in the Administration tab run the Windows command line Start Run enter cmd and confirm with th...

Отзывы: