Invacare® Pronto™ M41 Series
Removing Power Module
1.
Turn off electronics on remote.
2.
Remove seat, refer to
or move seat into service position, refer to
Moving Seat into Service Position (Modulite), page 25
.
3.
Remove top shroud, refer to
.
4.
Remove rear shroud, refer to
.
5.
Take exact note of positions of all cables and the
sockets that they are connected to. Mark the
connectors and sockets or take a photograph with a
digital camera.
6.
Remove plugs
A
from power module.
7.
Loosen and remove screws
B
.
8.
Remove power module.
Fig. 6-18
Installing Power Module
1.
Replace power module.
2.
Install parts in reverse order.
For details on cable routing, refer to LiNX
service manual.
3.
Update drive program if new software version is
available, refer to
Updating Software
.
Select driving program, refer to
Selection After Component Replacement, page 39
4.
Plug all free slots with suitable covering cap.
5.
Adapt drive program using programming software if
necessary.
6.
If LiNX system is used, perform calibration process,
refer to
Suggested programing procedure
in LiNX
service manual.
7.
Test all functions.
6.11.2 Checking Actuator
1.
Switch electronics OFF on remote.
2.
Move seat into service position (Modulite seat), refer to
6.7 Moving Seat into Service Position (Modulite), page 25
.
3.
Take exact note of positions of all cables and sockets that they are connected to. Mark connectors and sockets
or take photograph.
4.
Disconnect motor plug of motor to be tested from actuator module.
5.
Check electrical resistance at plug of actuator.
6.
If resistance is close to infinity, motor is probably burnt out.
7.
If resistance is below 1, motor has short-circuit.
8.
Motor must be replaced in both cases.
6.11.3 Updating Software
See LiNX service manual.
38