2016-0685
2017-10-02
AND CONTROL
UNIT
CONNECTORS
o-ring is in place, clean and not
damaged.
SPA IS TOO
NOISY IN
FILTRATION
MODE ONLY
-
Control base components
not securely attached.
-
Control base ground not
level and firm.
-
Spa filter motor failed.
-
Ensure control panel, back cover
and all inlet/outlet are securely
connected.
-
Ensure ground is level, firm and
smooth.
-
Replace the failed filter motor with
a new one.
INSUFFICIENT
CHLORINE
-
Insufficient operating time
of the sanitation system
and/or heater is running at
the same time.
-
Chlorine loss due to
intense sunlight exposure.
-
The bather load had
increased.
-
Clogged or dirty electrolyte
cell.
-
Increase the sanitation system
operating time and ensure the
heater is off during the sanitation
process. See “Sanitation System
Operating Instructions”.
-
Use a SPA cover when the SPA is
not in use and/or when the
sanitation system is operating.
-
Increase the sanitation system
operating time and test the water
using the test strips. See
“Sanitation System Operating
Instructions”.
-
Check and clean the cell if
necessary. See “Maintenance”.
BUBBLE AIR
BLOWER DOES
NOT WORK
-
Air blower pump is too hot.
-
Turn off and unplug the spa. Let it
cool down and restart all over
again.
-
If problem persists contact Intex
Service Center.
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing.)
E90
-
No water flow.
-
Turn off and unplug the control
unit.
-
Ensure the outlet cover grid is
clean and free from obstructions.
-
Clean or replace the cartridge, see
Maintenance and Storage section.
-
Ensure the in/outlet connections on
the spa tub and filter pump are not
blocked.
-
Keep the spa water properly
sanitized to ensure a clean and
unclogged filter cartridge.
-
Press the button to turn off the unit.
Release trapped air by unscrewing
the drain valve cap on the control
base side with a coin. Air has been
release once a steady stream of
water is glowing out from the drain
valve. Wait for 15 seconds and
screw the drain valve cap back.
Press the button to activate the
control panel buttons, and then run
the filter function by pressing the
button to push out any remaining
air in the system.
-
Turn off and unplug the control
unit. Plug the GFCI/RCD and
restart all over again.
-
If problem persists, contact Intex
Service Center.
E91
-
Dirt or scale on titanium
plates.
-
Low salt level / no salt.
-
Electrolyte cell cord is
loose.
- Possible
electrolytic
cell
-
Remove electrolytic cell for
inspection. Clean it if necessary.
See “Maintenance”.
-
Add salt. See “Salt Level
Information”.
-
Ensure that the cell cord is plugged