22
Electric connections
-
All electric cables are now to be connected to the controller.
The spring terminal is opened with the supplied screwdriver.
1.)
Insert slotted screwdriver in the top opening, then
press from top (arrow direction) and hold.
2.)
Insert cable in the opening underneath. Then release
the screwdriver (terminal closes) and remove.
Note:
-
NOTE: It must be observed during connection of the electrical
wiring that the bottom pump is the suction pump (clamp
terminal: suction pump) and the top pump is the back flushing
pump (clamp terminal: back flush pump).
Fig.: Operating mode spring termina
Finally, insert the cable bridge plug and firmly press until it is
fully inserted.
Fig.: cable bridge