4
CS6 Hard Wired for Power Management
use 14 gage Romex Wire
Same wall installation procedure as on Page 5 and 6
CS6
version was designed for limited amperage availability. If for example you use the microwave oven or your air
conditioner with the vacuum cleaner at the same time you circuit breaker might be overloaded.
After installing the following electrical connections, you can only run one appliance at a time.
The Following installation can be made only by a qualified electrician
For Power Management CS-6 only
Turn off the breaker to the area you will install the unit.
Find the power cable connecting the Microwave Oven to the Circuit Breaker.
Disconnect the exiting cable at the Microwave Oven. Reroute the cable to the Vacuum
cleaner installation.
In the back of the vacuum find the wire connections.
Strip all 3 wires by about 5/8”.
Tip: leave a loop in the wires from the vacuum to the wall where the cables are
securely attached.
From the Microwave (or other appliance) connect the Black wire to
(line)(switched),
the White wire into
“N”
(neutral) and connect the Ground wire under the washer screw
head to
“G”
.
From the Circuit Breaker run a new 14 or 12 gage Romex cable to the back of the
vacuum.
Strip the 3 wires and attach the Black to
, the White wire into the other
(neutral)
and the GROUND wire to the other
“G”
connection.
Attach the wire cover (supplied) over the connections by guiding the wires through the
opening at the bottom of the cover and screw cover into place.
On the front side of the vacuum, toggle the switch to “SOURCE”.
Switch-on the circuit breaker and check if the other appliance is operating.
Now toggle the switch on the Vacuum to “VAC”.
The other appliance will stop operating and the Central Vacuum is ready for use.