SEE PAGE 5 and 6 FOR THE POWER UNIT INSTALLATION
1.
Inside the vacuum chamber you will find the flanged pipe with 4 screws.
Attach the black flanged pipe into the back hole of the power unit.
2.
Install the vacuum valve about 3 to 4 feet from the vacuum. (The 2” dia.
Flex-hose comes standard at 4’ feet long.)
3.
With a circular saw, see above on the right and below, cut a 2-1/2” hole, with a
jig saw open the hole so that the vacuum valve is flush with the wall.
4.
Then route the 2” flex-hose form the vacuum to the valve.
5.
Route the supplied (low voltage, 24v.) white wire (the wire has 2 small leads) along the flex-hose
to the back of the vacuum to the 2 yellow pigtails.
IMPORTANT
:
Leave 3” of slack at the connections.
Do not remove the 2 screws at the valve completely
unscrew just enough to get the wires under the screw heads.
6.
Connect the yellow wires with wire nuts outside the vacuum housing.
7.
Secure the wires.
to be press-fit
to flanged pipe fitting at vacuum.
C) Flex-hose, 2” diameter,
D) Flanged pipe fitting D-920
attached to vacuum housing.
E) Vacuum valve with reducer
Note for circle
:
Screw the threaded pipe
coupling counterclockwise into
the flex-hose and press-fit the
other end into the Connectors
A
B
C
B
D
7
E
Содержание CS-RM
Страница 9: ...9 Installing dust bag and motor filter...