P/N 15654 (ML) • REV D • ISS 23AUG17
3 / 16
5. For latching LED: open J3 and provide a power reset by
removing power and resetting the LED.
6. Once installed, check that the alarm is received at the
control panel.
How test mode works
Test mode is activated by the hand-held tester when the tester
is held directly over the microphone and set off. The detector’s
LED will blink continuously for one minute. During this time, the
installer can test the unit using the instructions above. When
the system is armed and the GS903/913 trips to an alarm
condition, the LED will latch solid for four seconds and then
revert back to a one minute test mode. At the end of one
minute, the LED will extinguish if in “set up LED mode,” or the
LED will latch if set for
“latching LED”. Open spring clip for
latching LED.
Range of coverage
The GS903N/913N detectors are omni-directional, providing
360° coverage. Coverage is measured from the detector to the
point on the glass farthest from the detector. The detector can
be mounted as close as 1 m from the glass.
Mounted on opposite wall or adjoining walls, range is:
•
7.5 m for plate glass
•
6 m for tempered, laminated and wired glass
Mounted on the ceiling, maximum range is:
•
7.5 m for plate glass
•
6 m for tempered, laminated and wired glass
Mounted on same wall, maximum range is 4.5 m for all types
of glass.
For armour-coated glass, mount detector no more than 3.65 m
from glass.
Recommended glass size: Minimum 0.3 x 0.6 m or larger.
Glass thickness:
•
Plate: 2.4 to 6.4 mm
•
Tempered: 3.2 to 6.4 mm
•
Wired: 6.4mm
•
Laminated: 3.2 to 6.4mm
For best detection, avoid installing in
•
Rooms with lined, insulating or sound deadening curtains
•
Rooms with closed wooden window shutters inside
Specifications
Supply voltage
9 to 16 V DC
Current consumption:
GS903N
GS913N
12 mA typical, 25 mA max.
15 mA typical, 25 mA max.
Relay output
NC, open 4 seconds on alarm
On resistance
10 Ω, −5, +10
Off resistance
>20 MΩ
Maximum loop rating (relay or
tamper loop)
16 V DC, 50 mA
Lightning suppression
400 W for 1 msec. pulse
RF immunity
10 V/m from 80 MHz to 2.7 GHz
Microphone
Omni-directional electret
Temperature range
−18 to +50°C
Relative humidity
10 to 90% noncondensing
How to order
•
GS903N: Surface mount (white)
•
GS913N: Recessed (white)
•
GS905: Hand-held tester (white)
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Warnings and
Disclaimers
These products are intended for sale to, and
installation by, an experienced security
professional. UTC Fire & Security cannot provide
any assurance that any person or entity buying its
products, including any “authorized dealer,” is
properly trained or experienced to correctly install
security related products.
For more information on product warnings, refer
to www.utcfssecurityproducts.eu/productwarning/
or scan the code.
Certification
European Union
directives
UTC Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU, 2014/35/EU, and 2011/65/EU. For
more information see www.utcfireandsecurity.com
or www.interlogix.com.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/customer-
support