Interlogix DD100 Series Скачать руководство пользователя страница 3

 

P/N 145919999-

4 (ML) • REV K • ISS 14JUN19 

 

3 / 24 

5.  Select the mounting holes for flat wall (item 3) or for corner 

(item 4) mounting. 

If the detector is mounted on a swivel bracket, use the 
mounting hole for the swivel bracket instead (see Figure 2, 
item 2). 

6.  Use the base as a template for marking screw hole 

locations on the wall. 

7.  Fasten the base to the wall. 

8.  Strip 5 cm of the cable and pull it through the cable entry 

holes (Figure 1, item 7) and strain relief (item 1 in 
Figure 2). 

9.  Wire the detector as shown in Figure 3. If necessary, use 

an optional spare terminal (Figure 1, item 6). 

10.  Close the detector hinge cover (see Figure 5), insert the 

screw (Figure 1, item 5) and attach the cover plate 
(Figure 1, item 1). 

Pet immunity (DD100PI only) 

This detector is designed to be immune to pets below a certain 
size. Pets weighing less than 20 kg will not usually cause any 
problems in standard installation (see Figures 7 and 9). 
Consequently the detector is less sensitive to an intruder in the 
pet immune zone. Larger pets are accommodated by mounting 
the PI detector upside down 90 cm from the floor. The 
recommended minimum mounting height for pet immune 
applications is 2.4 m. 

Jumpers 

See Figure 3 for jumper location. 

J1: Dual loop feature (DD105 and DD105C only) 

 

Dual loop: With a dual loop, the tamper loop and the 
alarm loop can be monitored over two wires. 

Figure 4 shows examples of connecting detectors to 
the control panel and the different positions of jumper 
J1 in detectors. Item 1 shows a single device on a dual 
loop. Item 2 shows multiple devices on a dual loop. 

Note: 

3 to 7 are connection pins on PCB. Resistors 

are already assembled on PCB. 

In normal state (no alarm) the dual loop impedance is 
4.7 

kΩ. 

In alarm state the alarm relay contact opens and the 
impedance of the dual loop increases to 9.4 

kΩ, 

indicating an alarm. When the detector housing is 
opened, the tamper circuit opens and the dual loop is 
interrupted, indicating a tamper alarm. 

 

Standard alarm loop: The tamper output is isolated 
from the alarm relay output and the EOL resistor in the 
tamper circuit is short-circuited. 

Terminals 3 and 4 of the alarm relay output must be 
used to connect to the control panel. 

Terminal 5 cannot be used to connect an end-of-line 
resistor. In this case use an optional spare terminal in 
the base of the detector (Figure 1, item 6). 

 

End-of-line loop: Tamper output is isolated from the 
alarm relay output. 

The impedance of the tamper loop is now 4.7 kΩ. 

Terminals 4 and 5 of the alarm output must be used for 
connecting to the control panel. Impedance of the 
alarm relay loop is 4.7 kΩ. 

J2: LED function 

 

On: The LED is enabled. 

 

Off/Remote: The LED is disabled. It may be enabled 
remotely by applying a 0 V potential to terminal 8. 

To walk test the detector, make sure jumper J2 is in the On 
position, or in the Off/Remote position when the LED is 
enabled remotely. 

J3 and J4: Range adjustment 

PIR and microwave ranges can be adjusted independently by 
setting J3 and J4. 

Always select the appropriate range setting for the dimensions 
of the area to be protected. Verify the coverage pattern and 
adjust range settings as required. 

 

J3 

MW range 

 

J4 

PIR range 

 

10 m (DD100x) 
12 m (DD105x) 

 

 

10 m (DD100x) 
12 m (DD105x) 

 

6 m (DD100x) 
7 m (DD105x) 

 

 

6 m (DD100x) 
7 m (DD105x) 

Window mask 

Figure 10 shows the window mask. 

The mask is pre-fitted to the inside of the detector window and 
is used to mask objects that are close to (within 1.5 m) or 
directly under the detector. This disables the part of the 
curtains detecting an object whose closeness might otherwise 
cause a false alarm. 

Remove this mask to detect undercrawl. 

Specifications 

Input power 

9 to 15 VDC (12 V nom.) 

Peak-to-peak ripple 

2 V (at 12 VDC) 

Current consumption 
 

Normal operation 

 

Alarm 

 
11.5 mA nom. 
15 mA max. 

Mounting height 

1.8 m to 3.0 m 

Target speed range 

0.2 m/s to 3.0 m/s 

Microwave frequency 

2400.0 to 2483.5 MHz 

Maximum power output 

1 mW 

Maximum microwave output power at 
1 m (continuously) 

0.005 µW/cm² 

Alarm output 

80 mA at 30 VDC 

Tamper output 

100 mA at 30 VDC 

Содержание DD100 Series

Страница 1: ...DD105 DD105C 4 5 6 B A C 1 2 3 4 5 6 7 5 5 cm J2 J3 J4 J1 1 2 0V 12V 1 2 3 4 5 6 7 8 LED SPARE LED 33R SPARE LED SPARE SPARE 0V 12V 1 2 3 4 5 6 7 8 LED 33R 4K7 4K7 Panel Dual loop zone Panel Dual loo...

Страница 2: ...iew Strong air draughts on the detector Large animals in a field of view Obscuring the detector field of view with large objects such as furniture Microwave hazards Mounting surfaces susceptible to vi...

Страница 3: ...oop is interrupted indicating a tamper alarm Standard alarm loop The tamper output is isolated from the alarm relay output and the EOL resistor in the tamper circuit is short circuited Terminals 3 and...

Страница 4: ...equivalent new equipment or dispose of it at designated collection points For more information see www utcfssecurityproducts eu recycle Contact information www utcfireandsecurity com or www interlogix...

Страница 5: ...tes J1 skal v re isat i nederste stilling isolerede alarm sabotage kredse Enkelt balanceret med indbyggede endemodstande Sabotageudgang og alarm udgang er adskilte I serie med hver udgang er der en 4...

Страница 6: ...rtende Eindringrichtung quer diagonal zu dem Montageort des Melders erfolgen Die Dualtechnik Signalauswertung dieses Melders ist sehr resistent gegen ber Falschmeldungsquellen Vermeiden Sie dennoch po...

Страница 7: ...urch die Klemme 8 des Melders eine Fernschaltung 0 V der Gehtest LED erfolgen Bei VdS Installation zu beachten Nur in Klasse A Installationen darf die LED dauerhaft in Funktion geschaltet sein Bei Kla...

Страница 8: ...mit diesem Symbol gekennzeichnet sind d rfen nicht als unsortierter st dtischer Abfall in der europ ischen Union entsorgt werden F r die korrekte Wiederverwertung bringen Sie dieses Produkt zu Ihrem l...

Страница 9: ...rma de sabotaje Lazo de alarma est ndar La salida de sabotaje es independiente de la salida de rel de alarma Los terminales 3 y 4 son la salida del rel de alarma y los terminales 6 y 7 corresponden a...

Страница 10: ...nos no clasificados en la Uni n Europea Para que se pueda realizar un reciclaje adecuado devuelva este producto a su representante de ventas local al comprar un equipo nuevo similar o des chelo en los...

Страница 11: ...ucle et l autre en mode multi d tecteurs par boucle Dans ce mode l imp dance de la boucle est de 4 7 k en situation normale pas d alarme ou d AP En cas d alarme provenant d un d tecteur l imp dance de...

Страница 12: ...ences applicables et aux dispositions de toutes les r gles et r glements applicables y compris mais sans s y limiter de la Directive 2014 53 EU Pour plus d informations voir www utcfssecurityproducts...

Страница 13: ...nza misurata ai capi dei due fili di 4 7 k in caso si presenti un allarme il contatto di allarme si aprir e quindi la resistenza misurata risulter di 9 4 k indicando un allarme Quando il coperchio del...

Страница 14: ...questo dispositivo conforme ai requisiti applicabili e alle disposizioni di tutte le norme e regolamenti applicabili inclusi ma non limitati alla direttiva 2014 53 EU Per ulteriori informazioni vedere...

Страница 15: ...end is zal het sabotage circuit open zijn en de Dual Loop is onderbroken en er verschijnt een sabotage alarm Standaard alarm loop Sabotage uitgang is ge soleerd van de alarm relais uitgang en de End o...

Страница 16: ...lijn Producten met deze label mogen niet verwijdert worden via de gemeentelijke huisvuilscheiding in de Europese Gemeenschap Voor correcte vorm van kringloop geef je de producten terug aan jou locale...

Страница 17: ...ilkobling til betjeningspanelet Utgang 5 kan ikke benyttes til tilkoble en endemotstand I dette tilfellet benyttes en ekstra reserveutgang p basis av detektoren figur 1 enhet 6 Enkelbalansert sl yfe S...

Страница 18: ...izacja czujnika Czujnik serii DD100 jest dualnym czujnikiem antyw amaniowym stosuj cym do detekcji ruchu pasywn podczerwie PIR z weryfikacj poprzez detekcj mikrofalow Czujnik nale y tak zainstalowa ab...

Страница 19: ...rmowego Impedancja linii sabota owej wynosi teraz 4 7 k Zaciski 4 i 5 wyj cia alarmowego musz by u yte do pod czenia do centrali alarmowej Impedancja linii alarmowej wynosi 4 7 k J2 Dioda LED W czona...

Страница 20: ...ity com lub www interlogix com Informacje na temat pomocy technicznej mo na znale na stronie www utcfssecurityproducts pl PT Instru es de Instala o Instalac o do detector Este um detector de intrus o...

Страница 21: ...ara ligar ao painel de controlo A imped ncia da loop de rel do alarme de 4 7 k J2 Fun o LED On O LED est activado Off Remote O LED est desactivado Pode ser activado remotamente aplicando 0 V ao termin...

Страница 22: ...ity com ou www interlogix com Para assist ncia ao cliente consulte www utcfssecurityproducts eu SV Installationsanvisning Placering av detektorn Detektorn r en PIR detektor och b r installeras s att m...

Страница 23: ...n m ste du st lla omkopplare J2 i l get ON eller i l get OFF REMOTE f r fj rrstyrning J3 och J4 Justering av r ckvidden R ckvidden f r PIR och mikrov gorna justeras var och en f r sig med hj lp av omk...

Страница 24: ...ngar och produkts kerhet se https firesecurityproducts com policy product warning eller skanna QR koden Certifiering DD100PI EN 50131 2 4 2008 Testad och certifierad av Applica Test Certification UTC...

Отзывы: