• Install the detector fully on the mounting bracket (trim plate) by rotating the
detector in a clockwise direction. NOTE: The detector will mount to the bracket
in four positions (every 90 degrees).
6. The detector is now activated. After installation / activation, test your alarm as
described in Operation and Testing section.
Resetting a Detector’s Wireless Interconnect Settings
If you experience a delay or problem during wireless interconnection setup, you might
need to start over as if the detector is first removed from its packaging. Also, this "out-
of-box" mode can be used to attempt to reset/clear a network error condition.
1. Place and hold a magnet for 4 seconds on the cover at the designated location per
Figure 4. The detector will chirp once when the magnet is detected, then the
detector will chirp twice and the button will start flashing the RED LED rapidly to
indicate the proper mode has been entered to reset the wireless settings.
Figure 4
2. Press and hold the Test/Hush button for approximately eight seconds while the
RED LED is rapidly flashing. After four seconds, two beeps will occur (do not
release the button). After eight seconds, three beeps will occur. The button can
now be released.
3. Observe two cycles of RED LED on/off, one cycle of GREEN LED on/off
4. The RED LED will begin fading on/off every three seconds.
5. If no further steps are taken within 15 minutes of resetting the detector to "Out-of-
Box" mode, the RED LED will fade on/off for approximately 30-40 seconds, and the
interconnect function will turn off. The detector will then perform as a standard
standalone alarm.