17 P/N 466-5307
• REV A • ISS 15MAR17 ©2017 United Technologies
Corporation
Figure 6
3. After the tab is broken, use the screwdriver to turn the slotted arrow to the
"Permanently Disable Detector/Discharge Battery" location. This will disable the
detector, stop the low battery or end of unit life
“chirps” and render the detector
safe for disposal by draining the battery. Reference FIGURE 6.
Troubleshooting Guide
Trouble Condition
Visual Indication
Audible
Indication
Action:
Fault Mode/Fatal
Error
One AMBER LED
blink every 5
seconds.
Detector chirps
every 30 seconds.
1. Push the Test/Hush button
once to attempt to reset the
detector.
The RED LED will blink out an
Error Code (number of blinks)
when the Test/Hush button is
pushed/released once. Report
the number of blinks to
Customer Service, if needed.
2. Clean your detector. See
Section 12, "Cleaning Your
Detector" for instructions.
Network Error
One AMBER LED
blink every 5
seconds.
Detector chirps
every 30 seconds.
1. Push the Test/Hush button
once to silence the audible
indication for 24 hours at a
time.
The RED LED will blink out an
Error Code (number fo blinks)
when the Test/Hush button is
pushed/released once. Report
the number of blinks to
Customer Service, if needed.
2. Following instructions in
Section 4.3, "Resetting a
Detector’s Wireless Settings",
then attempt to rejoin the
network by following the
instructions in Section 4.2,
"Adding Another Detector to
an Existing Wireless Network
Between Detectors (Wireless
Interconnect)".
*If the error persists, remove,
discharge, and replace the
detector as soon as possible.