6 P/N 466-5307
• REV A • ISS 15MAR17 ©2017 United Technologies Corporation
or wall, the "A" line on the mounting bracket must be parallel with the hallway when
ceiling mounted, or horizontal when wall mounted.
• Install the detector fully on the mounting bracket (trim plate) by rotating the
detector in a clockwise direction.
NOTE:
The detector will mount to the bracket
in 4 positions (every 90 degrees).
7. The detector is now activated. After installation / activation, test your alarm as
described in Operation and Testing section.
Adding Detectors to an Existing Wireless Interconnected Network
For various reasons, you might want to add additional detectors to your existing
wireless interconnection network.
1. Remove the new detector from its packaging.
2. Place and hold a magnet for four seconds on the cover of an existing detector in
the network at the designated location per figure 4. The detector will beep once
when the magnet is detected, then the detector will beep twice and the button will
start flashing the RED LED rapidly to indicate the proper mode has been entered
to reset the wireless interconnect settings.
3. Push and hold the test button on any existing detector until two beeps are heard
(approximately four seconds), and then release the button.
• The button-pushed detector will cause the GREEN LED to fade on/off on each
existing detector to signal that the wireless interconnection network has been
opened.
NOTE:
From this point, you have fifteen (15) minutes to power up the new
detector.
3. Power up the new wireless unit by twisting the detector onto the mounting bracket
(trim plate) to activate the battery, or by carefully turning the activation wheel with a
screwdriver. See Figure 3.
• The new unit's RED LED will fade on/off every three seconds as it searches
for the network.
• A slow GREEN LED fading on/off confirms the new unit has found and joined
the existing wireless interconnection network.
4. Wait fifteen (15) minutes for the network setup to timeout, OR to immediately close
the network, push and hold the test button until two beeps are heard
(approximately four seconds), and then release the button.
• GREEN LED flashes once every 60 seconds on the new detector to indicate
normal operation.
5. After selecting the proper location for your detector, attach the mounting bracket to
the wall or ceiling. To ensure aesthetic alignment of the detector with the hallway,
or wall, the "A" line on the mounting bracket must be parallel with the hallway when
ceiling mounted or horizontal when wall mounted.