![Interlogix CDX-135Z Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/interlogix/cdx-135z/cdx-135z_installation-manual_2077323005.webp)
5 P/N 466-5307
• REV A • ISS 15MAR17 ©2017 United Technologies Corporation
2. Power on all detectors by attaching the detectors onto the mounting bracket (trim
plate) to activate the battery, or by carefully turning the activation wheel with a
screwdriver. See Figure 3.
Figure 3
• The GREEN LED will fade on and off once, then the RED LED will begin
fading on/off every 3 seconds.
NOTE:
If no further steps are taken within 15 minutes of initial power up, the
wireless function will turn off. The unit will then perform as a standard single station
detector.
NOTE:
At any time during wireless setup, if you have a problem, reset the unit's
wireless settings as described in section
“Resetting a Detector’s Wireless Settings”
3. Push and hold the Test/Hush button on any one detector until two beeps are heard
(approximately 4 seconds) and then release the button. This detector will
automatically create a new wireless network.
• A brief series of quick GREEN LED blinks will occur and then the GREEN LED
will fade on/off every second on the button-pushed detector (network creator).
4. Wait for the other wireless detectors to join the wireless network.
• A brief series of quick GREEN LED blinks will occur and then the GREEN LED
will fade on/off approximately every 3 seconds.
NOTE:
At this point, you can push/release the test button once on any detector,
and the RED LED will flash the number of enrolled detectors.
5. Wait for the network setup to timeout (approximately 15 minutes), OR to
immediately close the network, push the Test/Hush button until two beeps are
heard (approximately 4 seconds) and then release the button.
• Network closed sound on each detector confirms network has been closed.
GREEN LED flashes once every 60 seconds to indicate normal operation.
6. After selecting the proper location for your detector, attach the mounting bracket to
the wall or ceiling. To ensure aesthetic alignment of the detector with the hallway,