40
If you are installing a drive that connects to an adapter card, see the vendor’s
documentation for installing the adapter card and required cables. See the “Adding
Expansion Cards” section above for details.
If you are installing a removable disk drive module, see the vendor’s documentation for
installing the module, removing terminators, and setting the SCSI ID.
NOTE
Internal SCSI drives are not terminated. The internal SCSI cable provides termination. You
must disable termination on any drive that you install in the system.
Device Locations
You can add optional mass storage devices to the internal and external drive bays. The
following table provides the drive locations and related information. See the figure below.
Location
Drive
Peripheral Bay
Max Bay Capacity
SCSI ID
1
System disk drive
Internal
3.5-inch x 1.0 or 1.6-inch
0
2
Optional disk drive
Internal
3.5-inch x 1.0 or 1.6-inch
1
3
Optional disk drive
Internal
3.5-inch x 1.0-inch
2
4
OptAdd-on device
External
5.25-inch x 1.6-inch
3
5
Add-on device
External
5.25-inch x 1.6-inch
4
6
Floppy drive
External
3.55-inch x 1.0-inch
—
7
CD-ROM
External
5.25-inch x 1.6-inch
—
NOTE
You can install a total of three 3.5-inch x 1.0-inch drives or a total of two 3.5-inch x 1.6-inch
drives in the internal drive bay.
The following figure shows drive locations. Devices are installed in all locations for figure.
The CD-ROM, floppy drive, and system drive are standard. Other devices are available as
options.