16
External Bay Disk Drives
If a removable disk module is installed in the external bay, see the vendor documentation for
disk drive and module replacement instructions.
To replace an external bay disk drive:
1. Disconnect the SCSI cable and power cable from the disk drive.
2. Remove the two screws that secure the external bay disk drive tray to the chassis. See the
following figure.
External bay mounting screws
3. From inside the chassis, push the tray out of the external bay, grasp the front of the tray,
and then slide it out of the bay.
4. Remove the screws that secure the disk drive to the tray and remove the drive.
5. Do all of the following:
−
Note the SCSI ID jumper settings on the old drive
−
Set the SCSI ID on the new drive to the same ID as the old drive
−
Disable termination on the new drive
See Chapter 6, “Peripherals,” for details on these tasks.
6. Place the disk drive in the tray, align the mounting holes, and install the mounting screws
that secure the disk drive to the tray. See the following figure.