Tête + Tetrapad Manual
●
Bank CV
: CV Offsets Current/Played Position linearly.
With this assignment, you can use the
Bank CV
to directly select any available voltage bank.
For example, assume you have Tetrapad configured for 16 Voltage Banks. Positive voltages
will select bank numbers higher than the current bank (roughly one every 1/3 Volt when
16 Banks are used). Once the highest bank number is reached (16 in this example), the next
voltage increase will wrap the bank selection around to Bank 1. Negative voltages, as you
would expect, select lower numbered banks — also wrapping (to Bank 16) once Bank 1 is
reached.
●
Bank CV (CLK)
: Similar to the
Bank CV
option, except CV control is not continuous. Rather,
the incoming CV is sampled by the clock (using either the internal clock or an external clock
patched into Tête’s
CLK
input), and is held until the next clock. This enables you to
synchronize bank changes to a clock.
●
Bank CV (Trig)
: Similar to the
Bank CV
option, except CV control is not continuous. Rather,
the incoming CV is sampled on the leading edge of any signal patched into an input (
RESET
or
TRIG
) that’s assigned to the “
Mod Trig
” function in the CV Setup Menu. It is then held until
the next trigger. This enables you to synchronize bank changes to an external trigger source.
●
Bank CV (Pad)
: Similar to the
Bank CV
option, except CV control is not continuous. Rather,
the incoming CV is sampled each time you touch a pad, and is held until the next touch. This
enables you to synchronize bank changes to touches on Tetrapad’s pads.
●
Bank X CV
: CV Offsets Current/Played Position on the X Axis.
Banks are arranged within a grid. The number of banks determines the size of the grid.
Specifically:
With this assignment, you can use the
Bank X CV
to select between four different voltage
banks along the current bank’s row.
For example, if Bank 6 is current and you send positive control voltages to the CV input, they’ll
first select Bank 7, then Bank 8, and then wrap back around to Bank 5. At this point, bank
selection will stop since you will have scolled through all options on the X-axis. Negative
voltages select banks to the left of the current one, wrapping accordingly.
Page 123
Содержание Tete
Страница 9: ...T te Tetrapad Manual PART ONE INSTALLATION Page 8...
Страница 14: ...T te Tetrapad Manual PART TWO OVERVIEW Page 13...
Страница 29: ...T te Tetrapad Manual PART THREE COMBO MODE Page 28...
Страница 35: ...T te Tetrapad Manual Combo Mode Unipolar Fader Page 34...
Страница 39: ...T te Tetrapad Manual Combo Mode Bipolar Fader Page 38...
Страница 43: ...T te Tetrapad Manual Combo Mode Crossfader Page 42...
Страница 49: ...T te Tetrapad Manual Combo Mode Euclidean Page 48...
Страница 56: ...T te Tetrapad Manual Combo Mode Switches Page 55...
Страница 59: ...T te Tetrapad Manual Combo Mode LFO Page 58...
Страница 64: ...T te Tetrapad Manual PART FOUR NOTES MODE Page 63...
Страница 65: ...T te Tetrapad Manual NOTES MODE Page 64...
Страница 87: ...T te Tetrapad Manual PART FIVE VOLTAGES MODE Page 86...
Страница 88: ...T te Tetrapad Manual VOLTAGES MODE Page 87...
Страница 96: ...T te Tetrapad Manual PART SIX MENUS Page 95...
Страница 136: ...T te Tetrapad Manual PART SEVEN LOOPING SEQUENCING Page 135...
Страница 165: ...T te Tetrapad Manual PART EIGHT MISCELLANEOUS Page 164...