Tête + Tetrapad Manual
●
Loopy Length
: If the
feature is engaged, then a CV patched into the assigned jack will
modify the Loopy length. At 0V, Loopy is set to its minimum length. At +5V, Loopy plays at its
maximum length. Values in between scale the Loopy Length accordingly.
●
Loopy Shift
feature is engaged, then a CV patched into the assigned jack will
shift Loopy’s start point forward or backward. Positive voltages shift Loopy’s start point later in
the recording (wrapping around to the beginning when you shift Loopy’s start point past the
end of the recording). Negative voltages shift Loopy’s start point earlier in the recording
(wrapping around to the end when you shift Loopy’s start point past the beginning of the
recording).
●
Slew
: CV input continuously controls the Slew rate. Positive voltages increase the slew from
its current amount. Negative voltages decrease it. Note that you cannot set slew rates less
than ‘instantaneous’ nor can you set slew rates longer than those available on Tetrapad itself.
●
Slew (CLK)
: Similar to the
Slew
option, except CV control is not continuous. Rather, the
incoming CV is sampled by the clock (using either the internal clock or an external clock
patched into Tête’s
CLK
input), and is held until the next clock. This enables you to
synchronize slew rate changes to a clock.
●
Slew (Trig)
: Similar to the
Slew
option, except CV control is not continuous. Rather, the
incoming CV is sampled on the leading edge of any signal patched into an input (
RESET
or
TRIG
) that’s assigned to the “
Mod Trig
” function in the CV Setup Menu. It is then held until the
next trigger. This enables you to synchronize slew rate changes to an external trigger source.
●
Slew (Pad)
: Similar to the
Slew
option, except CV control is not continuous. Rather, the
incoming CV is sampled each time you touch a pad, and is held until the next touch. This
enables you to synchronize slew rate changes to touches on Tetrapad’s pads.
●
Level
: Uses the CV input to continuously scale the stored voltage values.
In this case, incoming CV acts as a multiplier. At +5 V, 100% of the stored voltage is sent to
the output. At 2.5V, 50% of the stored voltage is sent to the output. At 0V, 0% of the stored
voltage is sent to the output. Negative voltages scale and invert the stored voltages.
NOTE: If the input CV is 0V, then you will get no output voltages from your Tetrapad (since 0V
means you transmit 0% of your stored value). So if you select this option, you’ll definitely need
to patch a CV source into the input.
●
Level (CLK)
: Similar to the
Level
option, except CV control is not continuous. Rather, the
incoming CV is sampled by the clock (using either the internal clock or an external clock
patched into Tête’s
CLK
input), and is held until the next clock. This enables you to
synchronize level changes to a clock.
●
Level (Trig)
: Similar to the
Level
option, except CV control is not continuous. Rather, the
incoming CV is sampled on the leading edge of any signal patched into an input (
RESET
or
TRIG
) that’s assigned to the “
Mod Trig
” function in the CV Setup Menu. It is then held until the
next trigger. This enables you to synchronize level changes to an external trigger source.
Page 120
Содержание Tete
Страница 9: ...T te Tetrapad Manual PART ONE INSTALLATION Page 8...
Страница 14: ...T te Tetrapad Manual PART TWO OVERVIEW Page 13...
Страница 29: ...T te Tetrapad Manual PART THREE COMBO MODE Page 28...
Страница 35: ...T te Tetrapad Manual Combo Mode Unipolar Fader Page 34...
Страница 39: ...T te Tetrapad Manual Combo Mode Bipolar Fader Page 38...
Страница 43: ...T te Tetrapad Manual Combo Mode Crossfader Page 42...
Страница 49: ...T te Tetrapad Manual Combo Mode Euclidean Page 48...
Страница 56: ...T te Tetrapad Manual Combo Mode Switches Page 55...
Страница 59: ...T te Tetrapad Manual Combo Mode LFO Page 58...
Страница 64: ...T te Tetrapad Manual PART FOUR NOTES MODE Page 63...
Страница 65: ...T te Tetrapad Manual NOTES MODE Page 64...
Страница 87: ...T te Tetrapad Manual PART FIVE VOLTAGES MODE Page 86...
Страница 88: ...T te Tetrapad Manual VOLTAGES MODE Page 87...
Страница 96: ...T te Tetrapad Manual PART SIX MENUS Page 95...
Страница 136: ...T te Tetrapad Manual PART SEVEN LOOPING SEQUENCING Page 135...
Страница 165: ...T te Tetrapad Manual PART EIGHT MISCELLANEOUS Page 164...