Tête + Tetrapad Manual
CV Setup: Input X, Y and Z (Voltages Mode)
The CV Setup menu changes somewhat depending on whether Tête/Tetrapad is operating in Combo,
Notes, or Voltages mode. This section discusses the CV setup options that are available when you’re
using Voltages Mode.
At the top of the CV Setup menu are three voltage display bars. These display graphically the X, Y
and Z CV voltages (post Tête’s attenuverters). Bars extending to the right of center indicate positive
CV, while bars extending to the left of center indicate negative CV.
Use these CV meters along with Tête’s associated X, Y and Z attenuverters to modify and monitor the
voltage being sent through to the assigned destination. Tête’s CV inputs will read sources of up to
±10V, but only ± 5V is needed to sweep the full range of the input, so you can use the attenuverters
and CV meters to dial down extreme input voltages. Note that attenuverers are ignored for any CV
assignments that read 1 V/oct.
The following options are available for X, Y and Z assignment in Voltages Mode:
● - (off)
: Any signal patched into the corresponding CV input jack is ignored.
●
Reset*
: An input trigger patched into the corresponding CV input jack causes the current
loop/sequence to reset to the beginning.
●
Run*
: A +5V gate is required in order for the current Sequence or Loop to play. Tête must be
in a play state (the
PLAY (
)
button is solid green) in order for the Run feature to work. A
sequence/loop will run for as long as a +5V signal appears at the jack, and will pause when
the signal drops back to 0V.
●
Looper*
: With this assignment, Tête’s Looper uses the
TRIG
input to define a loop’s start
time and length (rather than using the internal or external clock). In addition, this assignment
redefines
Loop Length
(as set in the Mode Setup menu) as the “number of pulses on the
TRIG inputs,” rather than the “number of clocks pulses.”
●
Tggl Loopy*
: An input trigger patched into the corresponding CV input jack toggles
on/off.
●
Gate Loopy*
: An input gate patched into the corresponding CV input jack turns
When the gate is high, Loopy is on. When the gate is off, Loopy is off.
Page 119
Содержание Tete
Страница 9: ...T te Tetrapad Manual PART ONE INSTALLATION Page 8...
Страница 14: ...T te Tetrapad Manual PART TWO OVERVIEW Page 13...
Страница 29: ...T te Tetrapad Manual PART THREE COMBO MODE Page 28...
Страница 35: ...T te Tetrapad Manual Combo Mode Unipolar Fader Page 34...
Страница 39: ...T te Tetrapad Manual Combo Mode Bipolar Fader Page 38...
Страница 43: ...T te Tetrapad Manual Combo Mode Crossfader Page 42...
Страница 49: ...T te Tetrapad Manual Combo Mode Euclidean Page 48...
Страница 56: ...T te Tetrapad Manual Combo Mode Switches Page 55...
Страница 59: ...T te Tetrapad Manual Combo Mode LFO Page 58...
Страница 64: ...T te Tetrapad Manual PART FOUR NOTES MODE Page 63...
Страница 65: ...T te Tetrapad Manual NOTES MODE Page 64...
Страница 87: ...T te Tetrapad Manual PART FIVE VOLTAGES MODE Page 86...
Страница 88: ...T te Tetrapad Manual VOLTAGES MODE Page 87...
Страница 96: ...T te Tetrapad Manual PART SIX MENUS Page 95...
Страница 136: ...T te Tetrapad Manual PART SEVEN LOOPING SEQUENCING Page 135...
Страница 165: ...T te Tetrapad Manual PART EIGHT MISCELLANEOUS Page 164...