NSN 6130-99-391-3441 ()
Battery Charger Analyser : Operator Manual
6.3.2
Charge Operation
The will charge the battery at the current defined in (c) until the
target voltage (b) is reached, at which time it will then continue to charge the
battery at the current (c) until the additional time (d) has passed at which time
the charge will stop. If during the additional time (d) the battery terminal
voltage reached the overcharge voltage (a) then the charge will stop.
Note if the target voltage is not attained within 24 Hours the charger will stop
the process with a "time greater than 24H" warning.
0.1C & 0.2C PROCESS FLOW
Doc: DWG1030-25-R11 Operators manual.odt
Page 19 of 72
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17
START
MAINTAIN
CHARGE
CURRENT
TARGET
VOLTAGE
REACHED
?
ADDITIONAL
TIME EXPIRED
?
MAINTAIN
CHARGE
CURRENT
EXCEEDED
OVERCHARGE
VOLTAGE
?
END
COMPLETE
NO
YES
TIME > 24H
NO
END
OVERVOLTAGE
END
T > 24H