NSN 6130-99-391-3441 ()
Battery Charger Analyser : Operator Manual
19 Charge And Test Current Specifications
19.1 Charge Mode
Typical charge parameters are as follows: -
Battery Voltage
Maximum Charge Current
Standard Model
12V
40A
24V
25A
BAF50A Model
12V
50A
24V
25A
These current are quoted as nominal maximums. They must be de-rated for terminal
voltages exceeding certain levels as follows: -
For Battery Voltage Less than 19V parallel mode
Maximum current
Cut-off Voltage
Current drop per V thereafter
40A - Standard
16.2V
4A
50A - BAF50A
14.6V
4A
For Battery Voltage Equal or Greater than 19V
Maximum current
Cut-off Voltage
Current drop per V thereafter
25A - Both Models
40.15V
4A
Doc: DWG1030-25-R11 Operators manual.odt
Page 69 of 72