NSN 6130-99-391-3441 ()
Battery Charger Analyser : Operator Manual
6.3
Alkaline 0.1c & 0.2c Charge
6.3.1
Parameters Required
a) Overcharge Voltage
This voltage is the setting, which defines when the battery has reached an
overcharged state.
b) Target Voltage
This voltage is the charge voltage aimed for.
c) Charge Current
This is usually one tenth for 0.1C or one fifth for 0.2C of the battery capacity,
i.e. for a 44A/H battery this would be set to 4.4A or 8.8A respectively
d) Additional Charge Time
This time defines the additional charge time upon the target voltage being
achieved.
Doc: DWG1030-25-R11 Operators manual.odt
Page 18 of 72
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17