119
AC Power
•
Input voltage: Auto ranging, 90-264VAC
•
Input frequency: 47-63 Hz
•
Power factor correction: Per EN61000-3-2
•
Input current: 8.8 Amps RMS max @ 100VAC
•
Output power: 760 W peak
•
Efficiency: 91% @ 230VAC, 50% load
•
Variable speed “smart fans”
Supported Options
•
One DVD drive
•
Up to five PCI-E expansion cards
•
Up to two 2.5-inch internal SATA drives
Operating Environment
•
Temperature: 0° to 35°C
•
Temperature gradient: 20°C per hour
•
Relative humidity: 10 to 80 percent (non-condensing)
•
Humidity gradient: 10% per hour
•
Altitude: -200 to 10,000 ft.
•
Shock: 5G at 11ms, 1/2 sine wave pulse
•
Vibration: 0.15G at 5Hz to 400Hz
•
Acoustics: 7 Bels at normal operation tested to ISO7779
Non-Operating Environment
•
Temperature: -40° to 70°C
•
Relative humidity: 5% to 95% (non-condensing)
•
Altitude: -200 to 40,000 ft.
•
Shock: 10G at 11ms, 1/2 sine wave pulse
•
Vibration: 0.5G at 5Hz to 400Hz
Содержание SR2612UR - Server System - 0 MB RAM
Страница 14: ...xiv Intel Server System SR2612UR Service Guide ...
Страница 27: ...Intel Server System SR2612UR Service Guide 13 Figure 8 Intel Server System SR2612UR Configuration Diagram ...
Страница 98: ...84 Intel Server System SR2612UR Service Guide ...
Страница 102: ...88 Intel Server System SR2612UR Service Guide ...
Страница 104: ...90 Intel Server System SR2612UR Service Guide ...
Страница 136: ...122 Intel Server System SR2612UR Service Guide ...
Страница 158: ...144 Intel Server System SR2612UR Service Guide ...
Страница 159: ...Intel Server System SR2612UR Service Guide 145 ...
Страница 160: ...146 Intel Server System SR2612UR Service Guide ...
Страница 161: ...Intel Server System SR2612UR Service Guide 147 ...
Страница 162: ...148 Intel Server System SR2612UR Service Guide ...