background image

176

Intel

®

 Server System SR2600UR/SR2625UR Service Guide

After you have completed the six SAFETY steps above, you can 
remove the system covers. To do this:

1. Unlock and remove the padlock from the back of the system 

if a padlock has been installed.

2. Remove and save all screws from the covers.

3. Remove the cover(s).

For proper cooling and airflow, always reinstall the chassis covers 
before turning on the system. Operating the system without the 
covers in place can damage system parts. To install the covers:

1. Check first to make sure you have not left loose tools or parts 

inside the system.

2. Check that cables, add-in boards, and other components are 

properly installed.

3. Attach the covers to the chassis with the screws removed 

earlier, and tighten them firmly.

4. Insert and lock the padlock to the system to prevent 

unauthorized access inside the system.

5. Connect all external cables and the AC power cord(s) to the 

system.

A microprocessor and heatsink may be hot if the system has been 
running. Also, there may be sharp pins and edges on some board 
and chassis parts. Contact should be made with care. Consider 
wearing protective gloves.

Danger of explosion if the battery is incorrectly replaced. Replace 
only with the same or equivalent type recommended by the 
equipment manufacturer. Dispose of used batteries according to 
manufacturer's instructions.

The system is designed to operate in a typical office environment. 
Choose a site that is:

Clean and free of airborne particles (other than normal room 
dust).

Well ventilated and away from sources of heat including direct 
sunlight.

Away from sources of vibration or physical shock.

Isolated from strong electromagnetic fields produced by 
electrical devices.

In regions that are susceptible to electrical storms, we 
recommend you plug your system into a surge suppresser and 
disconnect telecommunication lines to your modem during an 
electrical storm.

Provided with a properly grounded wall outlet.

Provided with sufficient space to access the power supply 
cord(s), because they serve as the product's main power 
disconnect.

 

 

 

 

Содержание SR2600URLX

Страница 1: ...Intel Server System SR2600UR SR2625UR Service Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number E51243 007...

Страница 2: ...l may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airf...

Страница 3: ...additional details on the Intel Server System SR2600UR SR2625UR and the location where they can be found Chapter 2 provides a brief overview of the server system This includes a list of the server sys...

Страница 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...

Страница 5: ...heitshinweise zu Intel Serverplatinen und Servergeh usen auf der Intel Server Deployment Toolkit 3 0 CD oder unter http www intel com support motherboards server sb cs 010770 htm Consignes de s curit...

Страница 6: ...wer telephone and communication cables Turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Otherwise personal inju...

Страница 7: ...row sides of the jumper with the pliers never the wide sides Gripping the wide sides can damage the contacts inside the jumper causing intermittent problems with the function controlled by that jumper...

Страница 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...

Страница 9: ...nformation and Software 4 Chapter 2 Server System Features 7 Server System Feature Overview 9 Server System Components 11 Intel Server System SR2600UR Components 12 Intel Server System SR2625UR Compon...

Страница 10: ...ezel 47 Removing and Installing the System Cover 48 Removing the System Cover 48 Installing the Server System Cover 49 Removing and Installing the PCI Riser Assembly 50 Removing the PCI Riser Assembly...

Страница 11: ...moving a Slimline Optical Drive Intel Server System SR2625UR only 82 Installing a Slimline Optical Drive 82 Removing a Slimline Optical Drive 83 Installing a Tape Drive 84 Installing a Sixth Hard Disk...

Страница 12: ...lacing a Fixed Fan 135 Installing and Removing the Rack Handles 137 Installing the Rack Handles 137 Removing the Rack Handles 138 Chapter 4 Server Utilities 139 Using the BIOS Setup Utility 139 Enteri...

Страница 13: ...Deutsch 177 Fran ais 179 Espa ol 181 Italiano 183 Appendix G Safety Information 187 English 187 Server Safety Information 187 Safety Warnings and Cautions 187 Intended Application Uses 188 Site Select...

Страница 14: ...s sur l acc s au syst me 200 Avertissements sur le montage en rack 201 D charges lectrostatiques ESD 202 Autres risques 202 P riph riques laser 203 Espa ol 203 Informaci n de seguridad del servidor 20...

Страница 15: ...Backplane Components Rear View 35 Figure 21 Hot Swap SAS SATA Backplane Components Front View 36 Figure 22 Hot Swap SAS SATA Backplane Components Rear View 37 Figure 23 Cable Routing 40 Figure 24 Con...

Страница 16: ...65 Securing the Interposer Board to the Device Tray 79 Figure 66 Installing an Optical Drive Assembly into the Server System 79 Figure 67 Removing the Optical Drive Assembly from the Server System 80...

Страница 17: ...RAID Battery Backup Unit 117 Figure 109 Removing the Server Board 118 Figure 110 Installing the Server Board 119 Figure 111 Replacing the Backup Battery 121 Figure 112 Removing Power Supply Filler Pan...

Страница 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...

Страница 19: ...Feature Summary 9 Table 3 NIC LED Descriptions 31 Table 4 Setup Menu Key Use 139 Table 5 Power Supply Input Voltages 145 Table 6 Power Supply Output Capability 145 Table 7 System Environmental Specifi...

Страница 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...

Страница 21: ...tem SR2600UR SR2625UR ships with the Intel Server Board S5520UR For information about the server board see the Intel Server Board S5520UR Technical Product Specification The contents of the Intel Serv...

Страница 22: ...bay filler panel in the hardware box Optical drive tray assembly in the hardware box One 32 6mm flat screw for installing the optical drive component in the hardware box SR2600URLX only Two screws for...

Страница 23: ...ly Flex bay drive tray installed in the server system Two air baffles including a large air baffle and small air baffle installed in the server system SR2600URBRP only A large air baffle installed in...

Страница 24: ...oard layout connector pin outs timing information mechanical drawings and LED information Intel Server Board S5520UR Technical Product Specification Available at http www intel com p en_US support hig...

Страница 25: ...drivers firmware updates BIOS BMC FRUSDR and utilities Available for download at http www intel com p en_US support highlights server s5520ur Click the Software and Drivers link on the left side of t...

Страница 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...

Страница 27: ...y describes the main features of the Intel Server System SR2600UR SR2625UR This includes illustrations of the products a list of the server system features and diagrams showing the location of importa...

Страница 28: ...8 Intel Server System SR2600UR SR2625UR Service Guide Figure 2 Intel Server System SR2625UR AF002819...

Страница 29: ...ver Board S5520UR Processor Support for one or two Intel Xeon processors in FC LGA 1366 Socket B package with up to 95 W Thermal Design Power TDP 4 8 GT s 5 86 GT s and 6 4 GT s Intel QuickPath Interc...

Страница 30: ...LLC Pilot II controller with Integrated 2D Video Controller 32 MB DDR2 Memory LAN Two 10 100 1000 ports provided by Intel 82575 PHYs Expansion Capabilities The following riser card options are availab...

Страница 31: ...c LEDs Fan Fault DIMM Fault CPU Fault 5V STBY System Status System Identification POST Code Diagnostics Power Supply Up to two 750 W power supply modules Fans Intel Server System SR2600URBRP SR2625URB...

Страница 32: ...option shown C Air Baffles K Bridge Board D Power Distribution Module L Control Panel Standard control panel shown E Power Supply Modules supports up to two power supply modules M Flex Bay Sixth Hard...

Страница 33: ...ry B Air Baffles I System Fan Assembly redundant option shown C Power Distribution Module J Bridge Board D Power Supply Modules supports up to two power supply modules K Control Panel Standard control...

Страница 34: ...rs The ID LED is off by default and blue when activated by button or software DIMM Fault LEDs on the server board see Figure 5 help identify failed and failing DIMM slots The DIMM fault LEDs turn on a...

Страница 35: ...agnostic LEDs Server Board AF002833 I J G H J F D A B E C A POST Code Diagnostic LEDs B System Identification LED C Status LED D Memory 1 Fan Fault LED E CPU 1 Fan Fault LED F CPU 1 DIMM Fault LEDs G...

Страница 36: ...Intel Light Guided Diagnostic LEDs Passive Midplane Figure 7 Intel Light Guided Diagnostic LEDs Active Midplane A Fan 2 Fault LED B Fan 3 Fault LED C Fan 4 Fault LED D Fan 5 Fault LED E Fan 6 Fault L...

Страница 37: ...Intel Server System SR2600UR SR2625UR Service Guide 17 Figure 8 Intel Light Guided Diagnostic LEDs Standard Control Panel A Status LED B System Identification LED AF003002 A B...

Страница 38: ...ystem SR2600UR SR2625UR Service Guide Server Board Components This section helps you identify the components and connectors on the server board AF002696 E B C F G D A DD CC BB AA Z Y V W X U T J H I K...

Страница 39: ...MM slots K Processor 2 DIMM slots L Processor 2 Socket M CPU 2 Fan Header N Memory 2 Fan Header O Bridge Board Connector Intel Server Chassis P Front Panel Connector Q Fan Board Connector R 2x4 Power...

Страница 40: ...orce Update J1H2 If pins 2 3 are jumpered the Integrated BMC Force Update Mode is enabled These pins should be jumpered on 1 2 for normal system operation C BIOS Default J1E7 If pins 2 3 are jumpered...

Страница 41: ...istrator and user passwords are cleared within five to ten seconds after the system is powered on These pins should be jumpered on 1 2 for normal system operation E BIOS Recover J1D4 If pins 2 3 are j...

Страница 42: ...e optical drive must be purchased separately You cannot install both an optical drive and a USB floppy drive The drive in the optical drive carrier is NOT hot swappable The system power must be turned...

Страница 43: ...ard Disk Drives on page 90 Control Panel The Intel Server System SR2600UR supports the following types of control panels Standard Control Panel Intel Local Control Panel Standard Control Panel The fol...

Страница 44: ...performance Solid amber indicates a critical or non recoverable condition Blinking amber indicates a non critical condition No light indicates POST is running or the system is off G System Identificat...

Страница 45: ...green light indicates the system has power applied to it or the system is is S0 state Blinking green indicates the system is in sleep or ACPI S1 state No light indicates the power is off or the system...

Страница 46: ...d drives peripheral devices and the control panel For instructions on installing either of the front bezels see Installing the Front Bezel on page 47 The order numbers for the bezels are ADRBEZBLACK B...

Страница 47: ...TA hot swap 2 5 inch drives Note SAS drives are only supported on the Intel Server System SR2625URLX active version For instructions on installing hard drives see Installing a Hot swap SAS SATA Hard D...

Страница 48: ...accessory kits for these drives Flex Bay The server system also provides a multi purpose drive bay that can support either a tape drive or two additional fixed 2 5 inch hard drives This bay is located...

Страница 49: ...s Add in Card Slots I NIC 1 B Full height PCI Add in Card Slots J NIC 2 C Upper Power Supply Module K USB 6 D Upper Power Receptacle L USB 5 E Lower Power Receptacle M DB 9 Serial B Connector F Lower...

Страница 50: ...2600UR SR2625UR Service Guide Back Panel Connectors Figure 16 Back Panel Connectors A Mouse B Keyboard C Serial Port B RJ 45 D NIC 1 10 100 1000 Mb E NIC 2 10 100 1000 Mb F Video G USB Port 6 H USB Po...

Страница 51: ...following information Table 3 NIC LED Descriptions LED LED State Description Right Off No network connection Solid Green Network connection in place Blinking Green Transmit receive activity Left Off 1...

Страница 52: ...es required Passive Midplane The following diagram show the location for each connector found on the passive midplane Figure 17 Passive Midplane Components Note SATA connectors 6 and 7 are not used in...

Страница 53: ...ATA RAID Midplane Components AF002790 B F A L D E G H J I K C A Optional RAID Cache Battery Backup Connector G Fan 4 Power Connector B Midplane Power Connector H Fan 3 Power Connector C Mini DIMM Conn...

Страница 54: ...an interface between the midplane board and the system drives The following diagrams show the location for each connector found on the backplane Figure 19 Hot Swap SAS SATA Backplane Components Front...

Страница 55: ...Figure 20 Hot Swap SAS SATA Backplane Components Rear View AF002780 A B C D A Power Connector for sixth hard drive or tape drive or 2 5 inch fixed drives C Power Connector B SAS SATA Connector for six...

Страница 56: ...only The backplane serves as an interface between the midplane board and the system drives The following diagrams show the location for each connector found on the backplane Figure 21 Hot Swap SAS SAT...

Страница 57: ...s enabled the SATA Mode option can be set to either Legacy or Enhanced The Legacy and Enhanced modes affect the RAID configuration as follows Legacy supports four disk drives and does not provide RAID...

Страница 58: ...te system to be used on the managed server For instructions on installing the Intel Remote Management Module 3 see Installing and Removing the Intel Remote Management Module 3 on page 99 Rack Mount Op...

Страница 59: ...power cord Tools and Supplies Needed Phillips cross head screwdrivers 1 bit and 2 bit Needle nosed pliers Anti static wrist strap and conductive foam pad recommended System References All references t...

Страница 60: ...ble routing Figure 23 Cable Routing AF002993 A Intel Remote Management Module 3 optional B I O Module optional C Power Supply D Bridge Board E Midplane Board Active shown F Power Distribution Board G...

Страница 61: ...em SR2600UR SR2625UR Service Guide 41 Fan Connections Use the figures below to determine the proper fan connections Figure 24 Connecting the Non redundant Fan Power Cables to the Passive Midplane Boar...

Страница 62: ...ack option requires the system to be removed from the rack before servicing Basic slide rail kit This rack option requires the system to be removed from the rack before servicing The tool less full ex...

Страница 63: ...otted foot of a rail bracket between each nut bar and post 10 Align the face of the bracket foot with the inside edge of the rack post and firmly tighten the screws 11 Repeat steps 8 to 10 above to in...

Страница 64: ...f the system Note Remember to use the system LED to properly identify the system you are servicing 2 Pull system from rack until brackets are fully extended 3 Push in both clips on the brackets and sl...

Страница 65: ...nto the rack Note Beware of cables when re installing the system into the rack so that the cables do not get pulled or interfered with Removing and Installing the Front Bezel The front bezels are avai...

Страница 66: ...zel Supporting the Intel Local Control Panel Removing the Front Bezel If your system includes a front bezel follow these steps to remove the front bezel 1 Unlock the bezel if locked 2 Pull the bezel f...

Страница 67: ...s to install the front bezel Note Before installing the bezel you must install the rack handles For instructions see Installing the Rack Handles on page 137 To install the bezel follow these steps 1 A...

Страница 68: ...C power cable s Note A nonskid surface or a stop behind the server system may be needed to prevent the server system from sliding on your work surface To remove the server system cover follow these st...

Страница 69: ...he cover over the server system so that the side edges of the cover sit just inside the server system sidewalls 2 Slide the cover forward until it clicks into place see letter A in Figure 31 3 Optiona...

Страница 70: ...gure 33 and pull up to release it 3 Lift riser assembly straight up see letter B in Figure 33 Figure 32 Removing PCI Riser Assembly from the Server System 4 Do one of the following If you need to add...

Страница 71: ...in Figure 33 Figure 33 Installing PCI Riser Assembly into the Server System 3 Press down uniformly until the three hooks on the rear of the PCI riser assembly engage the server system back panel slot...

Страница 72: ...Disconnect any cables attached to any add in cards 2 Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly on page 50 3 Remove any add in cards from the PCI riser card For...

Страница 73: ...ructions see Removing the PCI Riser Assembly on page 50 3 Remove any add in cards from the PCI riser card For instructions see Removing a PCI Add in Card on page 55 4 Press and hold the blue riser loc...

Страница 74: ...upward and rotating clip to the fully open position see letter A in Figure 36 3 Open the front retention clip by pushing the blue latch in the direction shown and rotating 90 degrees outward see lett...

Страница 75: ...37 3 Open the front retention clip by rotating 90 degrees outward see letter B in Figure 37 4 Remove the PCI add in card from the riser card connector see letter C in Figure 37 Figure 37 Removing a F...

Страница 76: ...nstalling or Replacing the Processor on page 59 Return to these instructions to reinstall the processor air duct after installing your processor and heatsink Removing the Processor Air Duct To remove...

Страница 77: ...he Processor Air Duct Installing and Removing Memory The silkscreen on the board displays DIMM A1 DIMM A2 DIMM B1 DIMM B2 DIMM C1 DIMM C2 for DIMMs on CPU socket 1 and DIMM D1 DIMM D2 DIMM E1 DIMM E2...

Страница 78: ...M above the socket Align the notch on the bottom edge of the DIMM with the key in the DIMM socket see letter B in Figure 40 the arrow is pointing to the key in the socket 7 Insert the bottom edge of t...

Страница 79: ...rocessor Caution Processor must be appropriate You may damage the server board if you install a processor that is inappropriate for your server For a web link to the list of compatible processor s see...

Страница 80: ...e down and away from the socket to release it see letter A in Figure 41 6 Rotate the lever open all the way see letter B in Figure 41 Figure 41 Lifting the Processor Socket Handle 7 Push the rear tab...

Страница 81: ...packaging box and remove the protective shipping cover see Figure 44 Figure 44 Removing the Processor Protective Cover 11 Orient the processor with the socket such that the orientation notches on the...

Страница 82: ...e processor before installing the heatsink For instructions see Installing the Processor on page 60 Caution Improper installation can damage the heatsink Pay close attention to the steps and perform e...

Страница 83: ...n a diagonal manner according to the numbers shown in Figure 47 as follows a Starting with the screw at location 1 engage the screw threads by giving it two rotations in the clockwise direction and st...

Страница 84: ...osen b Proceed to the screw at location 2 and loosen it by giving it two rotations and stop c Loosen screws at locations 3 and 4 by giving each screw two rotations and then stop d Repeat steps 3a thro...

Страница 85: ...ge 56 3 Remove the heatsink For instructions see Removing the Heatsink on page 64 4 Unplug the processor fan cable from the server board 5 Open the processor socket lever see Figure 41 6 Open the CPU...

Страница 86: ...only when it is indicated as necessary for a component installation process Always operate your server system with the small air baffle in place The small air baffle is required for proper airflow wit...

Страница 87: ...tions in these sections only when it is indicated as necessary for a component installation process Always operate your server system with the fan baffle in place The fan baffle is required for proper...

Страница 88: ...68 Intel Server System SR2600UR SR2625UR Service Guide Figure 51 Removing the Fan Baffle AF003021 A B C...

Страница 89: ...lane see letter A in Figure 52 Orient the baffle such that the foam edges of the baffle contact the backplane and the bottom of the chassis 2 Slide the baffle in the direction shown see letter B in Fi...

Страница 90: ...airflow within the server system Removing the Large Air Baffle Before removing the air baffle note the routing of the cables over and under the air baffle if any since you will need to re route these...

Страница 91: ...oling To avoid possible damage to your server system do not use older style drive carriers Note The server system does not support all hard drives For a web link to a list of supported hard drives see...

Страница 92: ...se Figure 56 Removing Retention Device from Drive Carrier 4 Remove the hard drive from its wrapper and place it on an antistatic surface 5 Set any jumpers and or switches on the drive according to the...

Страница 93: ...black lever in the fully open position slide the drive assembly into the server system and push all the way until it stops see letter A in Figure 58 9 Close the lever to lock the drive assembly into...

Страница 94: ...he screw locations on the carrier Note To maintain proper system cooling all hard drive carriers must be installed in the server system and populated with either a drive or a drive blank 5 With the bl...

Страница 95: ...moving Hot swap Disk Carrier from the Server System 3 Remove the four screws securing the plastic retention device to the carrier see letter A in Figure 60 and remove the retention device see letter B...

Страница 96: ...rd disk assembly into the server system and push all the way until it clicks see letter A in Figure 62 9 Close the lever to lock the drive assembly into place see letter B in Figure 62 Figure 62 Insta...

Страница 97: ...drive or a drive blank 5 With the black lever held in the fully open position slide the drive carrier into the server system and push all the way until it clicks 6 Close the lever to lock the drive as...

Страница 98: ...rposer board connector into the matching connector on the back of the optical device see letter A in Figure 63 Figure 63 Installing the Interposer Board 3 Align the two holes on the left edge of the o...

Страница 99: ...d of the interposer board plugs into the matching socket on the backplane see letter B in Figure 66 8 Verify that the blue release lever on the tray locks into place 9 Optional For installing the opti...

Страница 100: ...it forward to release the optical drive tray assembly and slide the assembly out of the server system as shown in Figure 67 Figure 67 Removing the Optical Drive Assembly from the Server System 3 Press...

Страница 101: ...Guide 81 Figure 68 Removing the Slimline Optical Drive from the Tray 5 If no device will be installed in this location install a filler blank as shown in Figure 69 Figure 69 Installing Filler Blank in...

Страница 102: ...tlet To maintain proper system cooling a filler blank must be installed if you do not install a device at this location Installing a Slimline Optical Drive To install the slimline optical drive in Int...

Страница 103: ...m Removing a Slimline Optical Drive To remove the slimline optical drive from Intel Server System SR2625UR follow these steps 1 Press in on the plastic guide at the rear of the optical drive see lette...

Страница 104: ...er number ASR2500SATAPE or ADRTAPEKIT You must purchase a 3 5 inch tape drive Your server system must have a free SATA port on the server board or you must have an add in card that supports a tape dri...

Страница 105: ...the tape drive carrier kit using the four screws that were included with the tape drive kit as shown in Figure 74 Figure 74 Inserting a Tape Drive into the Carrier 3 Slide the tape drive carrier with...

Страница 106: ...in your system Depending on the midplane installed in your system do one of the following If you have an active midplane in your system do the following a Install one end of the short SATA cable to th...

Страница 107: ...kit order number ASR2500SIXDRV You must purchase an additional 3 5 inch hard disk drive After purchasing the sixth SAS SATA Hard Disk Drive HDD kit and the 3 5 inch hard disk drive use the following i...

Страница 108: ...xth hard disk drive kit comes with a power cable and two SATA cables Cabling for the sixth hard drive varies depending on which midplane you have in your system 4 Depending on the midplane installed i...

Страница 109: ...kit in a system with an active midplane OR If you have a passive midplane installed in your system do the following a Install one end of the power cable to the power connector on the backplane and the...

Страница 110: ...up to two fixed 2 5 inch solid state hard disk drives into Intel Server System SR2600UR SR2625UR your system must meet the following requirements You must purchase the 2 5 inch fixed hard disk drive k...

Страница 111: ...tion to these instructions refer to the instructions that came with your 2 5 inch hard disk drives for additional requirements 1 Remove the drive tray from the server system by pressing the blue relea...

Страница 112: ...2 Attaching the 2 5 inch HDDs to the brackets 3 Attach the drive assembly containing the two installed 2 5 inch HDDs to the drive tray using the four screws that are included with the 2 5 inch fixed h...

Страница 113: ...5 inch fixed HDD assembly 5 Connect one end of the power cable to the SAS SATA connector on the back side of the backplane see letter A in Figure 85 6 Connect the other end of the power cable to the...

Страница 114: ...the Front Bezel on page 46 With the bezel removed install the appropriate filler panel s drive blank or empty hard drive bay s as follows If you do not have an optical drive installed in the slimline...

Страница 115: ...remove the front bezel if it is installed For instructions see Removing the Front Bezel on page 46 With the bezel removed install the appropriate filler panel s drive blank or empty hard drive bay s...

Страница 116: ...er panel s to disengage it from the server system back panel and remove it see letter A in Figure 88 Note If you are installing an I O expansion module that uses only one slot remove the filler panel...

Страница 117: ...the PCI Riser Assembly on page 51 Removing the I O Expansion Module To remove the I O expansion module follow these steps 1 Remove the PCI riser assembly For instructions see Removing the PCI Riser As...

Страница 118: ...he server system For instructions see Installing the PCI Riser Assembly on page 51 Installing and Removing the Intel Remote Management Module 3 Installing the Intel RMM3 To install the Intel Remote Ma...

Страница 119: ...ee Figure 90 Figure 90 Removing the Intel RMM3 filler panel 4 Attach the Intel RMM3 to the module bracket with two screws see Figure 91 Figure 91 Installing the Intel RMM3 to the bracket 5 Connect one...

Страница 120: ...e chassis with two screws see letter B in Figure 93 Note The screws install from the back of the chassis Figure 93 Installing the Intel RMM3 to the Server System 8 Install the processor air duct For i...

Страница 121: ...age 50 2 Remove the processor air duct For instructions see Removing the Processor Air Duct on page 56 3 Remove screws from the back of the chassis see letter A in Figure 94 4 Disconnect the Intel RMM...

Страница 122: ...the PCI Riser Assembly on page 51 Replacing the Midplane Board The following sections describe how to replace the midplane board Removing the Midplane Board To remove the midplane board follow these s...

Страница 123: ...oard and lift the bridge board straight up see letter B in Figure 96 c Slide the board out of the fan assembly see letter C in Figure 96 Figure 96 Removing the Bridge Board from the Server System 6 Re...

Страница 124: ...oving the Midplane from the Server System Installing the Midplane Board To install the midplane board follow these steps 1 Position the midplane board over the retention pins see letter A in Figure 98...

Страница 125: ...board in the direction shown and insert the midplane into the backplane connector see letter C in Figure 98 Figure 98 Installing the Midplane into the Server System 4 Connect cables as necessary to t...

Страница 126: ...e Do NOT connect the HBA cable in a system with an active midplane or when using the SATA connectors on the server board to connect the hard drive SATA cables 6 Install the fan module For instructions...

Страница 127: ...r instructions see Installing the PCI Riser Assembly on page 51 Replacing the Backplane The following sections describe how to replace the backplane Removing the Backplane To remove the backplane foll...

Страница 128: ...ure 101 Figure 101 Removing the Backplane from the Intel Server System SR2600UR For Intel Server System SR2625UR do the following a Remove the blue thumbscrew from the backplane board see letter A in...

Страница 129: ...mponents on the backplane Set the backplane in place at the front of the server system with the sides of the board resting in the guides at the left and right sides of the server system b Slide the ba...

Страница 130: ...letter C in Figure 104 d Secure the backplane with the blue thumscrew see letter D in Figure 104 Figure 104 Installing the Backplane in the Intel Server System SR2625UR 4 Install hot swap drive carri...

Страница 131: ...all the RAID activation key by pushing straight down into the RAID key socket see letter A in Figure 105 5 Install the RAID mini DIMM as follows a Open both socket levers see letter B in Figure 105 b...

Страница 132: ...ve the large air baffle For instructions see Removing the Large Air Baffle on page 70 4 Remove the RAID activation key by lifting straight up see letter A in Figure 106 5 Remove the RAID mini DIMM as...

Страница 133: ...ns see Removing the Processor Air Duct on page 56 3 Remove the large air baffle For instructions see Removing the Large Air Baffle on page 70 4 Open the RAID battery backup unit cover see letter A in...

Страница 134: ...ackup unit follow these steps 1 Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly on page 50 2 Remove the processor air duct For instructions see Removing the Processo...

Страница 135: ...installed remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly on page 50 2 If installed remove the processor air duct For instructions see Removing the Processor Air Du...

Страница 136: ...Removing DIMMs on page 59 10 Remove the processor heatsink s and processor s For instructions see Removing the Heatsink on page 64 11 Remove the nine screws from the server board see letter A in Figur...

Страница 137: ...server board 4 Install memory For instructions see Installing DIMMs on page 57 5 Install the processor s For instructions see Installing the Processor on page 60 6 Install processor heatsink s For in...

Страница 138: ...rd used batteries according to manufacturer s instructions Advarsel Lithiumbatteri Eksplosionsfare ved fejlagtig h ndtering Udskiftning m kun ske med batteri af samme fabrikat og type Lev r det brugte...

Страница 139: ...ing the Power Supply Caution The power supply is only hot swappable if you have a redundant system with two power supplies installed If you only have one power supply installed before removing or repl...

Страница 140: ...ly is installed push the green latch in the direction shown see letter A in Figure 113 and remove the power supply module by pulling it out by the handle see letter B in Figure 113 to remove it Figure...

Страница 141: ...g the PCI Riser Assembly on page 50 2 If installed remove the processor air duct For instructions see Removing the Processor Air Duct on page 56 3 Remove the large air baffle For instructions see Remo...

Страница 142: ...supplies For instructions see Replacing the Power Supply on page 121 11 Connect all power cables to the server board 12 Install the fan module assembly For instructions see Replacing a Fan Module on...

Страница 143: ...st take the server out of service turn off all peripheral devices connected to the system turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet T...

Страница 144: ...rated with a control panel installed Caution The control panel is NOT hot swappable Before removing or replacing the control panel you must first take the server out of service turn off all peripheral...

Страница 145: ...Connect the USB and data cables to the replacement control panel see letter A in Figure 120 5 Feed the cables of the replacement control panel through the chassis opening see letter B in Figure 120 F...

Страница 146: ...uctions to replace a fixed fan module Replacing a Redundant Fan Module To replace a redundant fan module follow these steps 1 Remove the PCI riser assembly For instructions see Removing the PCI Riser...

Страница 147: ...ght up see Figure 122 Figure 122 Removing the Redundant Fan Module 8 Install the replacement fan module assembly as follows a Lower the fan assembly into the chassis see letter A in Figure 123 b Line...

Страница 148: ...all the bridge board For instructions see step 6 in Installing the Midplane Board on page 105 11 Install the large air baffle For instructions see Installing the Large Air Baffle on page 70 Re route c...

Страница 149: ...instructions see Removing the PCI Riser Assembly on page 50 2 Remove the processor air duct For instructions see Removing the Processor Air Duct on page 56 3 Remove the large air baffle For instructio...

Страница 150: ...d out of the system see Figure 124 Figure 124 Removing the Fixed Fan Module 8 Install the replacement fan module assembly as follows a Lower the fan assembly into the chassis see letter A in Figure 12...

Страница 151: ...bles to the midplane 10 Install the bridge board For instructions see step 6 in Installing the Midplane Board on page 105 11 Install the large air baffle For instructions see Installing the Large Air...

Страница 152: ...separately If one of the fans in the power supply fails the power supply must be replaced The system fans at the front of the server system can be individually replaced if one of them fails To replac...

Страница 153: ...system fans are NOT hot swappable Before removing or replacing a fan you must first take the server out of service turn off all peripheral devices connected to the system turn off the system by pressi...

Страница 154: ...d Fan Module on page 131 2 Pull out the plastic tabs on both ends to release the fan see letter A in Figure 128 3 Remove the fan from the fan module see letter B in Figure 128 Figure 128 Removing a Fa...

Страница 155: ...til it snaps in place Figure 129 Installing a Fan into the Fixed Fan Module 6 Reinstall the fixed fan module For instructions see steps 8 through 14 in Replacing a Fixed Fan Module on page 131 Install...

Страница 156: ...uide Figure 130 Installing the Rack Handle Removing the Rack Handles Remove the two screws holding the rack handle in place and remove the rack handle from the server system as shown in Figure 131 Fig...

Страница 157: ...POST after POST completes the memory test Press F2 to enter SETUP When the BIOS setup is entered the Main screen is displayed If You Cannot Access Setup If you are not able to access the BIOS Setup y...

Страница 158: ...he other keyboard but it has the same effect Enter Execute Command The Enter key is used to activate submenus when the selected feature is a submenu or to display a pick list if a selected feature has...

Страница 159: ...ng the BIOS update process a recovery process may need to be followed to return the system to service See Additional Information and Software on page 4 for a web link to necessary software and instruc...

Страница 160: ...he system during the BIOS update process The system will reset automatically when the BIOS update process is completed Note You may encounter a CMOS Checksum error or other problem after reboot If thi...

Страница 161: ...5 Wait ten seconds 6 Move the Password Clear jumper back to the Password Clear Protect position covering pins 1 and 2 7 Close the server system 8 Power up the server The password is now cleared and c...

Страница 162: ...tem Cover on page 48 3 Locate the BIOS Default jumper block at board position J1E7 4 Move the jumper from the normal operation position covering pins 1 and 2 to the Set Default position covering pins...

Страница 163: ...markings 4 Maximum rated input current is measured at 100 VAC and 200 VAC 750 W Single Power Supply Output Voltages The following table lists the total wattage available from the power subsystem for e...

Страница 164: ...Minimum OCP Limits Maximum OCP Limits Table 7 System Environmental Specifications Temperature Non operating Operating 40 C to 70 C 10 C to 35 C with the maximum rate of change not to exceed 10 C per h...

Страница 165: ...ssis Example SC5400 If third party chassis used indicate make and model Baseboard Information some information maybe found by accessing BIOS going through the Server Management menu System Information...

Страница 166: ...Firmware been tried Yes No Has the latest FRU SDR been tried Yes No Has the latest HSC been tried Yes No Processor information Thermal solution Heatsink examples 1U Passive w air ducting Active w fan...

Страница 167: ...tc Storage Devices Example SCSI SATA SAS USB Tape etc Operating System Information Example RedHat Enterprise Linux Microsoft Windows Server 2003 Service pack 1 OEM CD Manufacturer Version Language ver...

Страница 168: ...controller firmware version Has the latest RAID firmware been tried Yes No RAID driver version Has the latest RAID driver been tried Yes No RAID volumes configuration disks RAID level RAID volume use...

Страница 169: ...yes please provide a brief description below Do you have systems already purchased that are not being delivered to your customers because of this issue If yes please provide a brief description below...

Страница 170: ...152 Intel Server System SR2600UR SR2625UR Service Guide...

Страница 171: ...wo nibbles an upper nibble and a lower nibble The upper nibble bits are represented by Diagnostic LEDs 4 5 6 7 The lower nibble bits are represented by Diagnostics LEDs 0 1 2 and 3 If the bit is set i...

Страница 172: ...beep code is used in different contexts 0xF2h O O O O X X O X Seen at the start of Memory Reference Code MRC Start of the very early platform initialization code Very late in POST it is the signal tha...

Страница 173: ...e 0xB8h O X O O O X X X Channel Training Phase 0xB9h O X O O O X X O Memory Test Phase 0xBAh O X O O O X O X Memory Map Creation Phase 0xBBh O X O O O X O O RAS Initialization Phase 0xBFh O X O O O O...

Страница 174: ...such as ECC init 0x28h X X O X O X X X Testing memory PCI Bus 0x50h X O X O X X X X Enumerating PCI buses 0x51h X O X O X X X O Allocating resources to PCI buses 0x52h X O X O X X O X Hot Plug PCI co...

Страница 175: ...etting the console controller 0x79h X O O O O X X O Disabling the console controller 0x7Ah X O O O O X O X Enabling the console controller Keyboard USB only 0x90h O X X O X X X X Resetting the keyboar...

Страница 176: ...e media device 0xB9h O X O O O X X O Disabling removable media device 0xBAh O X O O O X O X Detecting presence of a removable media device CDROM detection etc 0xBCh O X O O O O X X Enabling configurin...

Страница 177: ...selection F Pre EFI Initialization PEI Core 0xE0h O O O X X X X X Started dispatching early initialization modules PEIM 0xE1h O O O X X X X O Reserved for initialization module use PEIM 0xE2h O O O X...

Страница 178: ...s has been called 0xF9h O O O O O X X O OS has switched to virtual address mode SetVirtualAddressMap has been called 0xFAh O O O O O X O X OS has requested the system to reset ResetSystem has been cal...

Страница 179: ...le knowledgebase to search for product information throughout the support site 2 If you are still unable to obtain a solution to your issue send an email to Intel s technical support center using the...

Страница 180: ...162 Intel Server System SR2600UR SR2625UR Service Guide...

Страница 181: ...essor used on this server board The final configuration of your end system product may require additional EMC compliance testing For more information please contact your local Intel representative Thi...

Страница 182: ...CES 003 Emissions USA Canada Verification CISPR 22 Emissions International EN55022 Emissions Europe EN55024 Immunity Europe EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe CE EMC Direc...

Страница 183: ...ominated Biphenyls Diphenyl Ethers PBB PBDE Quantity limit of 0 01 by mass 100 PPM for Cadmium California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate...

Страница 184: ...gulatory and safety markings In the event there is no room for a marking s on the chassis the information is provided here in this guide Table 10 Product Regulatory Compliance Markings Regulatory Comp...

Страница 185: ...KCC Mark Korean Communications Comission Korea Belarus Safety Compliance Mark Belarus Waste of Electronic and Electrical Equipment Recycling Mark Europe China Restriction of Hazardous Substance Envir...

Страница 186: ...ial Special handling may apply See www dtsc ca gov hazardouswaste perchlorate This notice is required by California Code of Regulations Title 22 Division 4 5 and Chapter 33 Best Management Practices f...

Страница 187: ...hr als ein Stromkabel Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide 2 Stromkabeln bevor Instandhaltung Nordic Countries Connection to Proper Ground Outlet WARNING Apparaten...

Страница 188: ...n then you are responsible for installing an AC power disconnect for the entire rack unit This main disconnect must be readily accessible and it must be labeled as controlling power to the entire rack...

Страница 189: ...wiring between the DC source and the server The branch circuit protection shall be rated minimum 75Vdc 10 A maximum per feed pair If the DC power system for the equipment rack is installed with more...

Страница 190: ...will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is e...

Страница 191: ...the Canadian Department of Communications CE Declaration of Conformity Europe This product has been tested in accordance to and complies with the Low Voltage Directive 73 23 EEC and EMC Directive 89 3...

Страница 192: ...nformation for configurations can be found on the Intel Server Builder Web site at the following URL http channel intel com go serverbuilder If you do not have access to Intel s Web address please con...

Страница 193: ...r power supply The power cord s is considered the disconnect device to the main AC power The socket outlet that the system plugs into shall be installed near the equipment and shall be easily accessib...

Страница 194: ...ocessor and heatsink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective glove...

Страница 195: ...ems zu unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die das System gesteckt wird sollte sich in der N he des Ger tes befinden und leicht zug nglich se...

Страница 196: ...Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten...

Страница 197: ...abeln zu gew hrleisten da der Stromanschlu des Produkts haupts chlich ber die Kabel unterbrochen wird Le bloc d alimentation de ce produit ne contient aucune pi ce pouvant tre r par e par l utilisateu...

Страница 198: ...t install sur l arri re du syst me d verrouillez le et retirez le 2 Retirez toutes les vis des panneaux et mettez les dans un endroit s r 3 Retirez les panneaux Afin de permettre le refroidissement e...

Страница 199: ...orages magn tiques il est recomand de brancher votre syst me un supresseur de surtension et de d brancher toutes les lignes de t l communications de votre modem durant un orage Muni d une prise murale...

Страница 200: ...una mu equera antiest tica sujetada a la toma de tierra del chasis o a cualquier tipo de superficie de metal sin pintar 6 No ponga en marcha el sistema si se han extra do las tapas del chasis Despu s...

Страница 201: ...o de trabajo normal Escoja un lugar Limpio y libre de part culas en suspensi n salvo el polvo normal Bien ventilado y alejado de fuentes de calor incluida la luz solar directa Alejado de fuentes de vi...

Страница 202: ...ate sul retro del sistema 5 Qualora si tocchino i componenti proteggersi dallo scarico elettrostatico SES portando un cinghia anti statica da polso che attaccata alla presa a terra del telaio del sist...

Страница 203: ...ttore Il sistema progettato per funzionare in un ambiente di lavoro tipo Scegliere una postazione che sia Pulita e libera da particelle in sospensione a parte la normale polvere presente nell ambiente...

Страница 204: ...186 Intel Server System SR2600UR SR2625UR Service Guide...

Страница 205: ...roduct certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the...

Страница 206: ...or physical shock Isolated from strong electromagnetic fields produced by electrical devices In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppre...

Страница 207: ...manufacturer for servicing When replacing a hot plug power supply unplug the power cord to the power supply being replaced before removing it from the server To avoid risk of electric shock turn off t...

Страница 208: ...as been running any installed processor s and heatsink s may be hot Unless you are adding or removing a hot plug component allow the system to cool before opening the covers To avoid the possibility o...

Страница 209: ...When replacing the battery use only the battery recommended by the equipment manufacturer Dispose of batteries according to local ordinances and regulations Do not attempt to recharge a battery Do no...

Страница 210: ...zugelassenen Komponenten die im vorliegenden Handbuch angegeben werden Die Verwendung anderer Produkte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt D...

Страница 211: ...trische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspannungsschutz anschlie en und bei einem Gewitter die Telekommunikationskabel zum Modem abziehen Eine...

Страница 212: ...rden k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein hot plu...

Страница 213: ...le Netzkabel ab bevor Sie Komponenten ein oder ausbauen die nicht hot plug f hig sind Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netzkabel ab bevor Sie es aus dem Server ausb...

Страница 214: ...ten Sie Platinen nur an den Kanten fest Legen Sie die Platinen nach dem Auspacken aus der Schutzh lle oder nach dem Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete statisch e...

Страница 215: ...installer ou de mettre jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livr es avec le produit ou publi es sur le site Web pour un produi...

Страница 216: ...lles que la lumi re directe du soleil et les radiateurs l cart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appareils lectriques ATTENT...

Страница 217: ...re d lectricit Attention Le bouton d alimentation indiqu par le symbole de mise en veille NE COUPE PAS compl tement l alimentation secteur du syst me car le courant de veille 5 V reste actif lorsque l...

Страница 218: ...les prises lectriques reli es la terre Les cordons d alimentation doivent r pondre aux crit res suivants Le cordon d alimentation doit supporter une intensit sup rieure celle indiqu e sur le produit L...

Страница 219: ...en contact avec un composant chaud lors d une installation chaud prenez toutes les pr cautions n cessaires lorsque vous retirez ou installez des composants connectables chaud Attention Pour viter de...

Страница 220: ...z ce que la carte ne glisse sur aucune surface Autres risques Remplacement de la pile Attention Il existe un risque d explosion si la pile n est pas correctement remplac e Lors du remplacement de la p...

Страница 221: ...montar y prestar los servicios para el servidor Debe ce irse a las directrices de esta gu a y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con l...

Страница 222: ...ar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por dispositivos el ctricos En zonas propensas a tormentas el ctricas se...

Страница 223: ...s de conexi n en funcionamiento Algunas fuentes de alimentaci n de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje Para evitar riesgos de choques electricos use precauci...

Страница 224: ...nte de alimentaci n deben estar conectados a los enchufes con una toma de tierra adecuada Advertencias el acceso al sistema Precauci n Para evitar lesiones personales o da os en la propiedad se aplica...

Страница 225: ...tidor del equipo se debe sujetar con un soporte fijo para evitar que se caiga cuando se extraiga un servidor o una pieza del mismo El bastidor del equipo debe instalarse siguiendo las instrucciones de...

Страница 226: ...gro de explosi n si la bater a no se reemplaza correctamente Al reemplazar la bater a utilice s lo la bater a recomendada por el fabricante del equipo Deseche las bater as respetando la normativa loca...

Страница 227: ...ispositivos l ser Precauci n Para evitar el riesgo de la exposici n a radiaciones o de da os personales No abra la caja de ning n perif rico o dispositivo l ser Los perif ricos o dispositivos l ser no...

Страница 228: ...210 Intel Server System SR2600UR SR2625UR Service Guide...

Отзывы: