28
Intel® Server System SR2600UR/SR2625UR Service Guide
Slimline Optical Drive Carrier
The server system includes a slimline optical drive carrier, which can be used to install a
single slimline SATA optical drive. The optical drive must be purchased separately.
The drive in the optical drive carrier is NOT hot-swappable. The system power must be
turned off to insert or remove the slimline optical drive carrier. For instructions on
installing an optical drive, see
“Installing a Slimline Optical Drive” on page 82
.
To use one of the drives provided by Intel, use the following order codes:
•
Slimline DVD-ROM Drive: AXXSATADVDROM
•
Slimline DVD-RW Drive: AXXSATADVDRWROM
Note:
The Intel
®
Server System SR2625UR does not support all slimline optical drives. For a
web link to a list of supported slimline optical drives, see
“Additional Information and
Software” on page 4
. Intel provides accessory kits for these drives.
Flex Bay
The server system also provides a multi-purpose drive bay that can support either a tape
drive or two additional fixed 2.5-inch hard drives. This bay is located next to the control
panel. To order the optional tape drive kit or fixed 2.5-inch hard drive kit, use the
following order codes:
•
SATA/SCSI Tape Drive Mounting Kit: ASR2500SATAPE or ADRTAPEKIT
•
2.5-inch Fixed Hard Disk Drive (HDD) Kit: ASR2600FXDRV
These drives are not hot-swappable. The system power must be turned off to insert or
remove the drives. For instructions on installing the 3.5-inch tape drive, see
“Installing a
Tape Drive” on page 84
. For instructions on installing the two fixed 2.5-inch hard drives,
see
“Installing the 2.5-Inch Fixed Hard Disk Drives” on page 90
.
Control Panel
The Intel
®
Server System SR2625UR supports the following types of control panels:
•
Standard Control Panel
•
Intel
®
Local Control Panel
Standard Control Panel
For information, see
“Standard Control Panel” on page 23
.
Intel
®
Local Control Panel
For information, see
“Intel® Local Control Panel” on page 24
.
Содержание SR2600URLX
Страница 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Страница 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Страница 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Страница 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Страница 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 28: ...8 Intel Server System SR2600UR SR2625UR Service Guide Figure 2 Intel Server System SR2625UR AF002819...
Страница 88: ...68 Intel Server System SR2600UR SR2625UR Service Guide Figure 51 Removing the Fan Baffle AF003021 A B C...
Страница 170: ...152 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 180: ...162 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 204: ...186 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 228: ...210 Intel Server System SR2600UR SR2625UR Service Guide...