65
Figure 48. Removing the Heatsink
Removing the Processor
To remove the processor, follow these steps:
1. Remove the PCI riser assembly. For instructions, see
“Removing the PCI Riser
Assembly” on page 50
.
2. Remove the processor air duct. For instructions, see
“Removing the Processor Air
Duct” on page 56
.
3. Remove the heatsink. For instructions, see
“Removing the Heatsink” on page 64
.
4. Unplug the processor fan cable from the server board.
5. Open the processor socket lever (see
Figure 41
).
6. Open the CPU load plate (see
Figure 42
).
7. Remove the processor.
8. If you want to replace the processor, see
“Installing the Processor” on page 60
.
Otherwise, install the protective socket cover over the empty processor socket.
A
B
TIM
This Side Up
Discard to Install CPU
This Side Up
Discard to In
stall CPU
2
3
1
4
C
Содержание SR2600URLX
Страница 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Страница 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Страница 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Страница 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Страница 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 28: ...8 Intel Server System SR2600UR SR2625UR Service Guide Figure 2 Intel Server System SR2625UR AF002819...
Страница 88: ...68 Intel Server System SR2600UR SR2625UR Service Guide Figure 51 Removing the Fan Baffle AF003021 A B C...
Страница 170: ...152 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 180: ...162 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 204: ...186 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 228: ...210 Intel Server System SR2600UR SR2625UR Service Guide...