Intel® Modular Server System MFSYS25 User Guide
31
Replacing the I/O Cooling Module
1. Review the safety and ESD information at the beginning of this manual and in the
appendices.
2. Press the I/O cooling module retention latch to release the I/O cooling module from
the module bay (see letter “A” in the following figure). Slide the I/O cooling module
out of the module bay (see letter “B”). Slide the replacement I/O cooling module into
the vacant module bay (see letter “C”) until the retention latch engages.
Warning: Replace the cooling module with another cooling module within two minutes.
Figure 22. Replacing an I/O Cooling Module
Installing and Removing Hard Drives
The Intel
®
Modular Server System MFSYS25 provides storage for installed compute
modules by way of an on-board storage bay combined with a storage management
module. The on-board storage bay supports the installation of up to 14 hot-swap 2.5-inch
SAS hard drives that are configured through the integrated server control software. Refer
to
“Configuring the Server Chassis” on page 41
Caution: Only hard drives validated for use in the Intel
®
Modular Server System MFSYS25 should
be installed. You may damage the Intel
®
Modular Server System MFSYS25 if you install a
AF002417
A
B
C
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
Содержание MFSYS25 - AXXPSU 1000W Power Supply Module
Страница 12: ...xii Intel Modular Server System MFSYS25 User Guide ...
Страница 22: ...10 Intel Modular Server System MFSYS25 User Guide ...
Страница 27: ...Intel Modular Server System MFSYS25 User Guide 15 Figure 7 Removing Management Module AF002436 C B A ...
Страница 110: ...98 Intel Modular Server System MFSYS25 User Guide ...
Страница 120: ...108 Intel Modular Server System MFSYS25 User Guide ...
Страница 124: ...112 Intel Modular Server System MFSYS25 User Guide ...
Страница 136: ...124 Intel Modular Server System MFSYS25 User Guide ...