62
Intel® Modular Server System MFSYS25 User Guide
•
Virtual drives can be quickly reassigned to different servers with a couple of mouse
clicks in the Intel
®
Modular Server Control UI without powering down the server or
storage pool.
•
Virtual drives in a single storage pool can be set to any RAID level that is supported
by the selected storage pool.
The steps to create a virtual drive are as follows:
1. Select the existing storage pool, which will contain the virtual drive.
2. Select
Create Virtual Drive
from the storage pool action menu. The following dialog
box will be displayed.
Figure 42. Create Virtual Drive Dialog Box
3. Enter a name for the virtual drive.
4. Select the RAID level for the virtual drive from the drop-down box. The options
available in the drop-down box are determined by the number of drives in the selected
storage pool.
5. Enter the size for the virtual drive. Depending on the RAID level selected, the
maximum size displayed may change (i.e., if mirroring is selected).
6. Select Wipe Master Boot Record (MBR) if an operating system will be installed on
this virtual drive. This will ensure a fresh volume for partitioning.
7. Controller Affinity is available for selection if two Intel® Storage Controllers are
installed in the system. This option determines the preferred storage controller to
handle requests for the new virtual drive. By default, this option is set to “any” but can
Содержание MFSYS25 - AXXPSU 1000W Power Supply Module
Страница 12: ...xii Intel Modular Server System MFSYS25 User Guide ...
Страница 22: ...10 Intel Modular Server System MFSYS25 User Guide ...
Страница 27: ...Intel Modular Server System MFSYS25 User Guide 15 Figure 7 Removing Management Module AF002436 C B A ...
Страница 110: ...98 Intel Modular Server System MFSYS25 User Guide ...
Страница 120: ...108 Intel Modular Server System MFSYS25 User Guide ...
Страница 124: ...112 Intel Modular Server System MFSYS25 User Guide ...
Страница 136: ...124 Intel Modular Server System MFSYS25 User Guide ...