IN-P

 

Multifunction Process 

Indicator.

 

Product Liability. 

This information describes our products. It does not constitute guaranteed properties and is not intended to affirm the 

suitability of a product for a particular application. Due to ongoing research and development, designs, specifications, and documentation are subject 

to change  

without notification. Regrettably, omissions and exceptions cannot be completely ruled out. No liability will be accepted for errors, omissions or  

amendments to this specification. Technical data are always specified by their average values and are based on Standard Calibration Units at 25C, 

unless otherwise specified. Each product is subject to the ‘Conditions of Sale’. 

Warning: These products are not designed for use in, and should not be used for patient connected applications. In any critical installation 

SECTION 1. –

 

Description. 

Ordering Information. 

www.intech.co.nz

 

Functions available on request: 

ITEMS 

CODE   

DESCRIPTION 

 SERIES 

IN-P- 

  

 Multifunction Process Indicator 

 ANALOGUE        

INPUTS  

PRC1- 

  

 1x 4~20mA / 0~10V input + 24Vdc excitation       

PRC4- 

  

 4x 4~20mA input + 24Vdc excitation 

TC1- 

  

 1x Thermocouple input 

 Types B, J, K, N, R, S, T 

TC4- 

  

 4x Thermocouple input 

 Types B, J, K, N, R, S, T 

RTD1- 

  

 1x RTD Pt100 input                                                                    

RTD4- 

  

 4x RTD Pt100 input                                                                   

 RELAY OUTPUTS 

N- 

  

 None                                                                                                                         

R2- 

  

 2x 5A relay outputs *

For PRC1 model only

 

R4- 

  

 4x 5A relay outputs 

R6- 

  

 6x 5A relay outputs *

For PRC1 model only

 

 ANALOGUE OUTPUT / RETRANSMISSION 

N- 

  

 None 

A- 

  

 1 x 4~20mA / 0~10V Analogue Output  

 COMMUNICATIONS 

 

* Not all Communication options are available for each input 

   model type, confirm with Intech.

 

N- 

  

 None 

WS232- 

  

 1x serial port Isolated RS232 

WS485- 

  

 1x serial port Isolated RS485                                                                                                

WEA-  

 

 With an Ethernet port (Ascii)                                  

WEM- 

  

 With an Ethernet port (Modbus)                                        

 POWER SUPPLY 

HV-   85~265Vac / 95~370Vdc 

LV-   15~48Vac / 10~72Vdc 

The IN-P Multifunction Process Indicator interfaces smoothly with a 

wide range of PLC and monitoring systems. Designed specifically for 

use in process applications, this indicator accepts a variety of inputs.  

The IN-P can be configured for many different analogue inputs and 

functions as listed below. 

Setup and calibration is simple, with on-screen, step-by-step  

instructions. The IN-P has a 6-digit LED display, 6 set-points and  

5 front panel buttons for easy setup and operator interface.  

Up to 6 relay outputs, an analogue output and/or communications can 

also be added. 

-  Auto or manual scanner with alarms. 

-  Maths functions, (i) √, (ii) Difference, (iii) Average, (iv) Hi / Lo Select. 

-  Hold, Tare, Reset (External switches connect to rear terminals). 

-  Flow Rate + Totalising. 

-  Energy display & totaliser (flow x ∆T). 

-  Step controller. 

-  Auto / Manual Station. 

-  Retransmission. 

-  Other Functions – please specify. 

-  Data Logging. 

C* 

D* 

E* 

G* 

Available on channel one only. 

Ordering Example: 

IN-P-RTD4-R2-N-WS485-HV

  Multifunction Process Indicator; 4x RTD Pt100 Inputs,  

2x 5A relay outputs, 1x serial port RS485,  

85~265Vac / 95~370Vdc Power Supply. 

(was IN-P4)

 

Содержание IN-P Series

Страница 1: ...IN P Multifunction Process Indicator Installation Guide...

Страница 2: ...tted Page 6 5 5 Wire your serial port if fitted Page 6 5 6 Wire your function pins if required Page 7 5 7 Power up your indicator Page 7 SECTION 6 Setup Calibration Page 7 6 1 Enter calibration PIN Pa...

Страница 3: ...R6 6x 5A relay outputs For PRC1 model only ANALOGUE OUTPUT RETRANSMISSION N None A 1 x 4 20mA 0 10V Analogue Output COMMUNICATIONS Not all Communication options are available for each input model type...

Страница 4: ...y will show the current VALLEY value see Section 11 E Function 2 This button is used to access the setpoint setup menu see Section 7 and the setpoint direct access menu see Section 8 SECTION 2 Specifi...

Страница 5: ...egin Before you can begin wiring the IP07 input module must be removed from the meter case so that the jumpers can be positioned for your input type Remove the plastic backing plate from the rear of t...

Страница 6: ...you do not have any relays fitted step 5 3 is skipped 5 4 Wire your analogue output if fitted Refer to 3 2I If your indicator has an analogue output fitted wire it as shown If you do not have an analo...

Страница 7: ...e the input mode in this section then the jumper plug on the input module must also be changed to match See Section 4 for more information D _ _ _ DECIMAL POINT POSITION scrolls across the display and...

Страница 8: ...lay value for cal high as at 6 5F D _ _ _ CALIBRATE ANALOG OUTPUT scrolls across the display and toggles with SKIP If you do not wish to calibrate your analogue output press P now If you would like to...

Страница 9: ...across the display and toggles with a calibration number Using the and buttons calibrate your low analogue output as required Then press P The display value is shown in internal units mA F _ _ _ CAL H...

Страница 10: ...scrolls across the display and toggles with the current selection Use the and buttons to adjust this value if required Then press P The hysteresis value defines the separation band between setpoint a...

Страница 11: ...rn to the operational display To view the minimum valley value Press the button for a second The word VALLEY appears on the display and toggles with the minimum measured process input value Press P to...

Страница 12: ...12 www intech co nz Christchurch Ph 64 3 343 0646 Auckland Ph 09 827 1930 Email sales intech co nz IN P 071216...