![INSYS MoRoS ADSL 2.1 PRO Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/insys/moros-adsl-2-1-pro/moros-adsl-2-1-pro_manual_2070346075.webp)
MoRoS ADSL 2.1 PRO
Functions
13.4.3
Switch Outputs
The MoRoS ADSL 2.1 PRO has digital outputs, whose status can be queried and
changed via the web interface.
The outputs can also be operated daily at a certain time. Moreover, it is possible to
operate the outputs by establishing a PPP connection, an OpenVPN tunnel, a PPTP
tunnel, or a serial Ethernet connection.
Configuration via the web interface
In order to query the status of the outputs, change to the menu "In-
/Outputs" and the page "Outputs". The status of the outputs is displayed
in the section "Manual switching of outputs" by the radio buttons next to
the text "Output 1/2".
In order to change the state of the outputs, select in the menu "In-
/Outputs" on the page "Outputs" in the section "Manual switching of
outputs" for the respective output "Idle condition" or "Operated
condition" using the radio buttons and click "OK".
In order to switch an output to operated condition daily at a certain time,
check in the section "Switching times Output 1/2" the checkbox
"Switches to operated condition at" and enter into the following field the
time for operating the respective output.
In order to switch an output to idle condition daily at a certain time,
check in the section "Switching times Output 1/2" the checkbox
"Switches to idle condition at" and enter into the following field the time
for releasing the respective output.
In order to configure output 1 for an operation with the presence of a
PPPoE connection, select under "Function of output 1" the option
"Switches to operated condition if a PPP connection is established". This
function is not effective, if the LAN ext interface is configured for a
PPPoA connection.
In order to configure output 2 for an operation with the presence of an
OpenVPN tunnel, select under "Function of output 2" the option
"Switches to operated condition if an OpenVPN tunnel is established".
In order to configure output 2 for an operation with the presence of an
PPTP tunnel, select under "Function of output 2" the option "Switches to
operated condition if an PPTP tunnel is established".
In order to configure output 2 for an operation with the presence of an
IPsec tunnel, select under "Function of output 2" the option "Switches to
operated condition if an IPsec tunnel is established".
In order to configure output 2 for an operation with the presence of a
serial Ethernet connection, select under "Function of output 2" the option
"Switches to operated condition if a serial Ethernet connection is
established".
Save your settings by clicking "OK".
75