![INSYS MLR 3G 2.0 Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/insys/mlr-3g-2-0/mlr-3g-2-0_manual_2070345085.webp)
MLR 3G 2.0
Functions
10.11.6
Updating the Firmware
You can update the firmware of the MLR 3G 2.0. The firmware is a combination of oper-
ating system and programs, in which the functions of the {{PRODUKTBEZEICHNUNG}}}
are implemented. To update the firmware, you will need a file with a new firmware,
which you can obtain from your sales partner or from INSYS MICROELECTRONICS. It is
possible that you get two files for extensive updates.
Note
Function loss due to faulty update!
A connection failure during the update and a following restart
may cause a loss of function of the MLR 3G 2.0.
As long as the red LED at the MLR 3G 2.0 is illuminated, you are
not permitted to perform any actions at the web interface, you
must not pull the power plug and you must not perform a re-
set.
After a failed update, do not restart the MLR 3G 2.0; contact the
support of INSYS MICROELECTRICS.
Note
Loss of availability!
Through a firmware update, your MLR 3G 2.0 may loose its
previous configuration. Your MLR 3G 2.0 can then only be ac-
cessed from the local network via its standard IP address
192.168.1.1.
Perform critical updates only at the site and contact the sup-
port of INSYS MICROELECTRONICS.
Complete update of the firmware of the MLR 3G 2.0
The following steps must be performed to update the firmware of a MLR
3G 2.0.
You have access to the web interface.
If you access the web interface of the MLR 3G 2.0 via a dial-up connection,
the connection must be maintained long enough to perform the uploads.
The option "Maximum connect-time" should be set to "0" for the update,
also the "Idle time".
You have ensured that the power supply of the MLR 3G 2.0 can not be
switched off during the update procedure.
You have the firmware file with the name "system_<rev>" and, if required,
the file "data_<rev>". The file(s) can be located on the PC from which you
want to perform the update.
1.
In the menu "System", switch to the page "Update".
85