CombiLock 200 simplex / pro / pro RFID
Handbuch V.1.10
58
INSYS locks
4.12
Enabling the Lock
(with electronic lock closed only):
Q
Master code (sample code)
Q
p
Lock enabled
4.13
Setting the Time and Date
Enter the date and time by entering numbers only
.
Entries for weekdays: 1 = Monday / 2 = Tuesday / 3 = Wednesday
/ 4 = Thursday/ 5 = Friday / 6 = Saturday / 7 = Sunday
Q
Master code (sample code)
Date, 28.12.14, for example
Time of day 15:00
Q
p
Day of week, 4 = Thursday, e.g.
4.14
Additional Functions CombiLock 200 pro
The following additional functions can be implemented with the help of unit CombiXT
and the configuring set:
Function
5.4.1.1
Required accessories
Unit CombiXT Parameterisation Set
CombiComm
Event recorder / Audit trail
(
256 events, date,
time)
-
⚫
Silent alarm / Duress alarm
⚫
-
External release
⚫
-
Open- / Close-signal
⚫
-
Mains power supply
⚫
-
⚫
required
-
not required