CombiLock 200 simplex / pro / pro RFID
Handbuch V.1.10
52
INSYS locks
3
Operating Instructions CombiLock simplex
3.1
Programming / Changing the Master Code
(Code 1)
(within 10 seconds after opening):
master code
new master code (sample code)
repeat master code
3.2
Programming / Changing the User Code (Code 2)
(within 10 seconds after opening):
master code
(when changing code, master
–
or user code input)
new user code (sample code)
repeat new user code
3.3
Deleting User Code
(within 10 seconds after opening):
Master code
3.4
Additional Functions CombiLock 200 simplex
In order to
Open with Timed Unlocking Delay
, enter the Code a second time after
the end of the unlocking delay. In case the second code input is not entered within
the set duration of the release period, opening with timed unlocking delay has to be
restarted from the beginning.
Timed delay
1
-
3
Minutes> Release
1
Minute
Timed delay
4
-
10
Minutes> Release
2
Minutes
Timed delay
11
-
99
Minutes> Release
3