CombiLock 200 simplex / pro / pro RFID
INSYS locks
73
Manual V.1.10
7.3
Mounting the Lock
Also see the assembly overview above.
Caution
Applying too much force can cause damage.
Consequences which might arise from not being aware
of the danger.
Do not use more torque than 1 Nm when fastening the
attachment ring and do not use more torque than 10 Nm
when fastening the lock.
1.
Check whether there are suitable bores in the safe door. If required, drill
bores, at this stage above all for the spindle variant A (Ø min. 8.2 mm, max.
12 mm).
Drill further bores, if required, before carrying out steps 3 - 6 (see below).
2.
Shorten spindle halves / shorten spindle. Assemble spindle variant A using 2
halve pipes. Thread the cable with its plugs through the spindle. Lead the
spindle through the safe door bore. Attach 2 adapters and stick together.
3.
Thread the keypad connector cable with its plug through the spindle
variant B and the centre axis of the electronic lock.
4.
Insert the connecting spindle into the keypad and adjust its position in
relation to the electronic lock.
5.
Slip-on the locked electronic lock onto the spindle.
6.
Use three steel machine screws (M6 x 30 mm, DIN 6912, flat form or the
corresponding inch threads) to affix the electronic lock so that permanent
and secure support is provided.
In order to avoid malfunctions, tighten down the mounting screws with a torque of
max. 10 Nm. If required, additionally use screw retention liquid of medium
mechanical strength
Installation options:
The electronic lock must always be located at right
angles to the keypad (four installation positions, each
offset 90° from the other).
INSYS Lock 200 simplex / pro / pro RFID
CombiControl CL38
Sample installation of electronic lock system CombiLock 200 simplex / pro / pro RFID
The bolt is not to be subjected to tension or pressure after installation.